Test Applications
78 BV10
UDP Echo Responder Test
UDP Echo Responder Test
The UDP Echo Responder test listens for UDP Echo messages and
responds with a reflected packet when all of the following criteria (as
defined in RFC962) are met:
UDP Responder control is enabled (default).
Destination MAC address equals the MAC address of the Test port.
VLAN ID equals the VLAN ID of the Test port (if configured).
Destination IP address equals the IP address of the Test port.
Protocol is UDP (17).
UDP destination port is 7 (UDP Echo, as per RFC862).
The UDP Echo Responder test supports wire-speed operation.
The UDP Echo Responder test can be enabled (default) or disabled. Refer
to udp-echo enable|disable on page 71 for more information.