Exfo FTB-500 (Window XP) Uživatelský manuál Strana 1

Procházejte online nebo si stáhněte Uživatelský manuál pro Měřící nástroje Exfo FTB-500 (Window XP). EXFO FTB-500 (Window XP) User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 405
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - User Guide

User Guide FTB-500

Strany 2

Certification Informationx FTB-500Certification InformationNorth America Regulatory StatementThis unit was certified by an agency approved in both Can

Strany 3 - End-User License Agreement

Working with Your Unit90 FTB-500Accessing Other ToolsAccessing Other ToolsYour unit comes with various tools that can help you better analyze or manag

Strany 4

Working with Your UnitFTB-500 91Printing DocumentsPrinting DocumentsYou can print documents and images directly from your unit by using either the PDF

Strany 5 - Contents

Working with Your Unit92 FTB-500Printing DocumentsTo print documents:1. Open a Web browser as follows:1a. Minimize the ToolBox window.1b. On the Windo

Strany 6

Working with Your UnitFTB-500 93Printing Documents6. Tap Print to start the printing process.7. If you selected PDFCreator, proceed as follows:7a. Ent

Strany 7 - FTB-500 vii

Working with Your Unit94 FTB-500Viewing PDF FilesViewing PDF FilesYou can view PDF files directly from your unit using the SumatraPDF reader. For more

Strany 8

Working with Your UnitFTB-500 95Taking Screen CapturesTaking Screen CapturesYou can take captures of what is displayed on your screen, directly from y

Strany 9 - FTB-500 ix

Working with Your Unit96 FTB-500Browsing the WebBrowsing the Web You can browse the Web directly from your unit, provided that you have access to an I

Strany 10 - Certification Information

Working with Your UnitFTB-500 97Accessing the Internet with a 3G USB Modem KeyAccessing the Internet with a 3G USB Modem KeyNote: Only administrator-l

Strany 11 - 1 Introducing the FTB-500

Working with Your Unit98 FTB-500Accessing the Internet with a 3G USB Modem KeyTo upgrade your unit to the latest System Upgrade and Platform component

Strany 12 - Main Features

Working with Your UnitFTB-500 99Accessing the Internet with a 3G USB Modem Key3. Install the retrieved kits on your unit:3a. Install the System Upgrad

Strany 13 - Introducing the FTB-500

FTB-500 11 Introducing the FTB-500Today’s network technology is more complex than ever. Thousands of components have to work in harmony and deployment

Strany 14

Working with Your Unit100 FTB-500Accessing the Internet with a 3G USB Modem Key4. Follow the on-screen instructions. You will know that the installati

Strany 15

Working with Your UnitFTB-500 101Accessing the Internet with a 3G USB Modem Key4. From the Windows desktop, tap the AirCard Watcher icon to start the

Strany 16

Working with Your Unit102 FTB-500Retrieving the GPS Location of Your UnitRetrieving the GPS Location of Your UnitWith the optional GPS USB key and the

Strany 17

Working with Your UnitFTB-500 103Retrieving the GPS Location of Your UnitTo upgrade your unit to the latest System Upgrade and Platform components:1.

Strany 18 - LED Panel Description

Working with Your Unit104 FTB-500Retrieving the GPS Location of Your UnitTo retrieve the GPS location of your unit:1. If necessary, turn on your unit

Strany 19 - Function Buttons Description

Working with Your UnitFTB-500 105Retrieving the GPS Location of Your UnitThe GPS coordinates are displayed.Note: As this is the case with any other GP

Strany 21

FTB-500 1076 Using the Optional Built-In Power Meter and VFL The FTB-500 can be equipped with an optical power meter to measure absolute power (dBm or

Strany 22

Using the Optional Built-In Power Meter and VFL108 FTB-500Accessing the Built-In Power MeterAccessing the Built-In Power MeterTo access the built-in p

Strany 23 - 2 Safety Information

Using the Optional Built-In Power Meter and VFLFTB-500 109Accessing the Built-In Power MeterBelow is a description of the Power Meter buttons and func

Strany 24 - Symbol Meaning

Introducing the FTB-5002 FTB-500Main FeaturesMain FeaturesFunction buttons Speaker StylusPower buttonLCD/TouchscreenModule-related LED panelUnit-relat

Strany 25 - Laser Safety Information

Using the Optional Built-In Power Meter and VFL110 FTB-500Nulling OffsetsNulling OffsetsTemperature and humidity variations affect the performance of

Strany 26 - Electrical Safety Information

Using the Optional Built-In Power Meter and VFLFTB-500 111Setting Thresholds and Correction FactorsSetting Thresholds and Correction FactorsYou can de

Strany 27 - FTB-500 17

Using the Optional Built-In Power Meter and VFL112 FTB-500Setting Thresholds and Correction FactorsYou may apply a correction factor (CF) to measured

Strany 28

Using the Optional Built-In Power Meter and VFLFTB-500 113Setting Thresholds and Correction FactorsTo set thresholds or correction factors:1. On the b

Strany 29

Using the Optional Built-In Power Meter and VFL114 FTB-500Setting Thresholds and Correction Factors4. Tap Edit. 5. Modify the thresholds or correction

Strany 30

Using the Optional Built-In Power Meter and VFLFTB-500 115Setting Reference Values on Your Power MeterSetting Reference Values on Your Power MeterIn R

Strany 31 - 3 Getting Started with Your

Using the Optional Built-In Power Meter and VFL116 FTB-500Measuring Power or LossMeasuring Power or Loss Measuring absolute power or link (insertion)

Strany 32 - 22 FTB-500

Using the Optional Built-In Power Meter and VFLFTB-500 117Measuring Power or Loss5. Using bulkhead adapters or the system patch panels, connect a fibe

Strany 33 - FTB-500 23

Using the Optional Built-In Power Meter and VFL118 FTB-500Measuring Power or LossTo view and edit power or loss measurements:1. Select the Measurement

Strany 34 - 24 FTB-500

Using the Optional Built-In Power Meter and VFLFTB-500 119Opening Results FilesOpening Results FilesYou can open results files that are stored on your

Strany 35 - FTB-500 25

Introducing the FTB-500FTB-500 3Main FeaturesUSB ports (2)Serial Port (male DB-9)Fiber inspection probe connectorBack supports Right side(four-slot mo

Strany 36 - 26 FTB-500

Using the Optional Built-In Power Meter and VFL120 FTB-500Opening Results Files3. From the given list of files, select the file to open.4. Confirm wit

Strany 37 - FTB-500 27

Using the Optional Built-In Power Meter and VFLFTB-500 121Clearing Measurements from the DisplayClearing Measurements from the DisplayWhen measurement

Strany 38 - Turning On the FTB-500

Using the Optional Built-In Power Meter and VFL122 FTB-500Adding Information to Your ResultsAdding Information to Your ResultsA report is available to

Strany 39

Using the Optional Built-In Power Meter and VFLFTB-500 123Printing Results ReportsPrinting Results ReportsYou can print reports directly from your uni

Strany 40 - Turning Off the FTB-500

Using the Optional Built-In Power Meter and VFL124 FTB-500Printing Results ReportsTo print a power measurement report:1. Connect a printer to your FTB

Strany 41

Using the Optional Built-In Power Meter and VFLFTB-500 125Identifying Fiber Faults Visually with the VFLIdentifying Fiber Faults Visually with the VFL

Strany 42 - 32 FTB-500

Using the Optional Built-In Power Meter and VFL126 FTB-500Identifying Fiber Faults Visually with the VFLTo activate the VFL and inspect a fiber:1. Cle

Strany 43

FTB-500 1277 Inspecting Fibers with a ProbeThe fiber inspection probe (FIP) is used to find dirty or damaged connectors by displaying an enlarged view

Strany 44 - Grounding Your FTB-500

Inspecting Fibers with a Probe128 FTB-500To inspect fibers with a probe:1. Connect the probe to your unit.For a probe of the FIP-400 series, connect i

Strany 45 - To secure your unit:

Inspecting Fibers with a ProbeFTB-500 1293. If the unit prompts you to select an application, tap the button corresponding to the probe that you want

Strany 46

Introducing the FTB-5004 FTB-500Main FeaturesBack support Right side(eight-slot model)Power Meter (optional)VFL (optional)Module slotsBottom supportFr

Strany 48 - 38 FTB-500

FTB-500 1318 Managing DataYou can copy, move, rename, delete files and folders directly on your unit. You can transfer files from your unit to a USB m

Strany 49 - Accessing and Exiting ToolBox

Managing Data132 FTB-500Transferring Data via BluetoothTransferring Data via BluetoothWith the optional Bluetooth device, you can transfer data betwee

Strany 50 - Starting Module Applications

Managing DataFTB-500 133Transferring Data via BluetoothThe procedure presented hereafter explains how to transfer data from your unit to a computer. D

Strany 51 - FTB-500 41

Managing Data134 FTB-500Transferring Data via BluetoothTo transfer data via Bluetooth:1. Configure your unit as follows:1a. Connect the Bluetooth devi

Strany 52

Managing DataFTB-500 135Transferring Data via Bluetooth1e. From the Options tab, under Discovery, select the Tur n discover y on check box.1f. Ensure

Strany 53 - Activating Software Options

Managing Data136 FTB-500Transferring Data via Bluetooth2. Configure the computer as follows:2a. Connect another Bluetooth device to one of the USB por

Strany 54 - 44 FTB-500

Managing DataFTB-500 137Transferring Data via Bluetooth7. Select the computer to which you want to transfer data as follows:7a. Tap Browse.7b. Select

Strany 55

Managing Data138 FTB-500Transferring Data via Bluetooth8. If you want to use a passkey, select the corresponding check box and enter the passkey.When

Strany 56 - 46 FTB-500

Managing DataFTB-500 139Transferring Data via Bluetooth11. On the computer, when the application prompts you, allow the connection and enter the passk

Strany 57 - Software

Introducing the FTB-500FTB-500 5Main FeaturesBack supportsDC input connector(for AC adapter/charger)Ethernet (RJ-45) portVideo out portModuleretaining

Strany 58

Managing Data140 FTB-500Connecting to a Wireless NetworkConnecting to a Wireless NetworkWith the optional Wi-Fi card (or a USB wireless adapter of you

Strany 59 - 4 Setting Up Your FTB-500

Managing DataFTB-500 141Connecting to a Wireless Network3. If it is not already done, configure the firewall as follows:3a. From the main window, sele

Strany 60 - Installing a Monitor

Managing Data142 FTB-500Connecting to a Wireless Network3e. Ensure that the File and Printer Sharing item is selected. 3f. Tap OK to confirm.4. Tap Ne

Strany 61

Managing DataFTB-500 143Connecting to a Wireless Network5. Double-tap Wireless Network Connection.6. If your unit is already connected to a wireless n

Strany 62 - Calibrating the Touchscreen

Managing Data144 FTB-500Connecting to a Wireless Network7. From the Wireless Network Connection window, select the wireless network to which you want

Strany 63 - FTB-500 53

Managing DataFTB-500 145Using the USB to RS-232 AdapterUsing the USB to RS-232 AdapterIf you want to transfer data between your unit and a device that

Strany 64 - Changing the Backlight Level

Managing Data146 FTB-500Using the USB to RS-232 AdapterTo use the USB/RS-232 adapter:1. Turn on both the unit and the serial device.2. Connect as show

Strany 65 - FTB-500 55

Managing DataFTB-500 147Using the USB to RS-232 Adapter3. From your unit, retrieve the COM port of the adapter as follows:3a. From the main window, se

Strany 66 - Keyboard

Managing Data148 FTB-500Using the USB to RS-232 Adapter3d. From System Properties, select the Hardware tab, then tap Device Manager.3e. Expand the Por

Strany 67 - FTB-500 57

Managing DataFTB-500 149Using the USB to RS-232 Adapter4. From your unit, configure the communication parameters as follows:4a. From the main window,

Strany 68 - 58 FTB-500

Introducing the FTB-5006 FTB-500Main FeaturesBack supportAC connectorBottom supportEthernet (RJ-45) portVideo out portModule retaining screwsLeft side

Strany 69 - FTB-500 59

Managing Data150 FTB-500Using the USB to RS-232 Adapter5. From the device, set the communications parameters.Note: The COM port number that you set on

Strany 70 - Installing a Pointing Device

Managing DataFTB-500 151Connecting to a VPN from Your UnitConnecting to a VPN from Your UnitNote: Only administrator-level users can install software

Strany 71 - FTB-500 61

Managing Data152 FTB-500Connecting to a VPN from Your UnitTo install a VPN client on your unit:1. If the date on your unit does not correspond to the

Strany 72 - Installing a Microphone

Managing DataFTB-500 153Using Your Unit as an FTP ServerUsing Your Unit as an FTP ServerIf you want your unit to act as an FTP server, you can use the

Strany 74 - Installing an Express Card

FTB-500 1559 Accessing Your Unit RemotelyYou can access your unit remotely from a computer using either the Remote Desktop Connection or TightVNC Clie

Strany 75 - FTB-500 65

Accessing Your Unit Remotely156 FTB-500Working with Remote DesktopWorking with Remote DesktopBy default, the remote access to your unit with Remote De

Strany 76 - 66 FTB-500

Accessing Your Unit RemotelyFTB-500 157Working with Remote DesktopTo allow the remote access to your unit with Remote Desktop:1. From the main window,

Strany 77 - FTB-500 67

Accessing Your Unit Remotely158 FTB-500Working with Remote Desktop5. Under Remote Desktop, select Allow users to connect remotely to this computer.6.

Strany 78 - 68 FTB-500

Accessing Your Unit RemotelyFTB-500 159Working with Remote DesktopTo access your unit remotely with Remote Desktop:1. Connect both the computer and yo

Strany 79

Introducing the FTB-500FTB-500 7Main FeaturesThe FTB-500 runs Microsoft Windows XP Professional for Embedded Systems, and the ToolBox software provide

Strany 80 - Setting Up Your FTB-500

Accessing Your Unit Remotely160 FTB-500Working with Remote Desktop6. In the Connecting to Remote Desktop window, in the Computer list, type the IP add

Strany 81 - FTB-500 71

Accessing Your Unit RemotelyFTB-500 161Working with Remote DesktopTo allow a user with limited accounts to use Remote Desktop:1. From the main window,

Strany 82 - 72 FTB-500

Accessing Your Unit Remotely162 FTB-500Working with Remote Desktop5. Under Remote Desktop, select Allow users to connect remotely to this computer.6.

Strany 83 - To add new input languages:

Accessing Your Unit RemotelyFTB-500 163Working with Remote Desktop7. From the Remote Desktop Users dialog box, tap Add.8. From the Select Users dialog

Strany 84 - 4. Select the Languages tab

Accessing Your Unit Remotely164 FTB-500Working with Remote Desktop9. Tap Find Now to let the system find and display the list of users.10. Select the

Strany 85 - FTB-500 75

Accessing Your Unit RemotelyFTB-500 165Working with Remote DesktopPreventing Users from Connecting with Remote DesktopYou can also configure the unit

Strany 86 - 76 FTB-500

Accessing Your Unit Remotely166 FTB-500Working with Remote Desktop3. Tap System.4. From the System Properties dialog box, tap the Remote tab.5. Under

Strany 87 - FTB-500 77

Accessing Your Unit RemotelyFTB-500 167Working With TightVNCWorking With TightVNCThe control of your unit with TightVNC requires the TightVNC Server (

Strany 88 - 78 FTB-500

Accessing Your Unit Remotely168 FTB-500Working With TightVNCConfiguring the TightVNC ServerThe TightVNC Server is already installed on your unit. You

Strany 89 - FTB-500 79

Accessing Your Unit RemotelyFTB-500 169Working With TightVNC6. In the Primary password and View-only password boxes, type the desired passwords.Note:

Strany 90

Introducing the FTB-5008 FTB-500LED Panel DescriptionLED Panel Description The LED panel on the front of the unit provides you with the status of the

Strany 91 - FTB-500 81

Accessing Your Unit Remotely170 FTB-500Working With TightVNCInstalling the TightVNC Viewer on a Client ComputerIf the TightVNC Viewer is not already i

Strany 92 - 3. Tap Power Options

Accessing Your Unit RemotelyFTB-500 171Working With TightVNCConnecting to Your Unit with TightVNCOnce the TightVNC Viewer is installed on your compute

Strany 93

Accessing Your Unit Remotely172 FTB-500Working With TightVNC5. On the Windows taskbar, tap Start, and then select All Programs.6. Select TightVNC, and

Strany 94 - 84 FTB-500

Accessing Your Unit RemotelyFTB-500 173Adding Exceptions to the FirewallAdding Exceptions to the FirewallNote: Only administrator-level users can add

Strany 95 - FTB-500 85

Accessing Your Unit Remotely174 FTB-500Adding Exceptions to the Firewall3. Tap Windows Firewall.4. Select the Exceptions tab.5. Tap Add Program to add

Strany 96 - Setting ToolBox Options

FTB-500 17510 Preparing for AutomationThe FTB-500 was designed to meet the requirements of automation and to facilitate its integration with your test

Strany 97 - FTB-500 87

Preparing for Automation176 FTB-500The choice of a technology will depend on your particular needs.For more information on programming aspects, see th

Strany 98

Preparing for AutomationFTB-500 177Linking Units with the Ethernet PortLinking Units with the Ethernet PortYour FTB-500 is equipped with an Ethernet p

Strany 99 - 5Working with Your Unit

Preparing for Automation178 FTB-500Linking Units with the Serial PortLinking Units with the Serial PortYour FTB-500 is equipped with a serial (RS-232)

Strany 100 - Accessing Other Tools

Preparing for AutomationFTB-500 179Getting Optimum Performance from Your FTB-500Getting Optimum Performance from Your FTB-500Several factors influence

Strany 101 - Printing Documents

Introducing the FTB-500FTB-500 9Function Buttons DescriptionFunction Buttons DescriptionThe FTB-500 is equipped with function buttons that give you ac

Strany 102 - 92 FTB-500

Preparing for Automation180 FTB-500Getting Optimum Performance from Your FTB-500 Output format (RS-232, ActiveX and TCP/IP): The FTB-500 provides the

Strany 103

Preparing for AutomationFTB-500 181Changing Communication SettingsChanging Communication SettingsCommunication settings cannot be modified without tur

Strany 104 - Viewing PDF Files

Preparing for Automation182 FTB-500Changing Communication Settings2. Under Platform Startup, determine whether your module applications will be starte

Strany 105 - Taking Screen Captures

Preparing for AutomationFTB-500 183Changing Communication Settings4. According to the communication type you have selected, customize the correspondin

Strany 106 - Browsing the Web

Preparing for Automation184 FTB-500Changing Communication SettingsTo revert to default general settings:1. Click the Restore Default Settings button.2

Strany 107 - FTB-500 97

Preparing for AutomationFTB-500 185Configuring DCOM Access to Your UnitConfiguring DCOM Access to Your UnitDCOM technology allows to control devices a

Strany 108 - IMPORTANT

Preparing for Automation186 FTB-500Configuring DCOM Access to Your UnitSetting the General Security ParametersNote: To run DCOMCNFG.EXE, you need admi

Strany 109

Preparing for AutomationFTB-500 187Configuring DCOM Access to Your Unit5. In the My Computer Properties dialog box, click the COM Security tab.6. Unde

Strany 110

Preparing for Automation188 FTB-500Configuring DCOM Access to Your Unit7. In the Access Permission dialog box, ensure that the Distributed COM Users g

Strany 111 - FTB-500 101

Preparing for AutomationFTB-500 189Configuring DCOM Access to Your UnitTo add a user explicitly:1. In the My Computer Properties dialog box, click the

Strany 112

ii FTB-500Copyright © 2009–2014 EXFO Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmit

Strany 113 - FTB-500 103

Introducing the FTB-50010 FTB-500Hard-Drive StructureHard-Drive StructureYour FTB-500 uses several hard-drive partitions for specific purposes.Automat

Strany 114

Preparing for Automation190 FTB-500Configuring DCOM Access to Your Unit4. In the Select Users or Groups dialog box, under Enter the object names to se

Strany 115 - FTB-500 105

Preparing for AutomationFTB-500 191Configuring DCOM Access to Your Unit6. Confirm the newly added user has remote access permission as follows:6a. In

Strany 116

Preparing for Automation192 FTB-500Configuring DCOM Access to Your Unit9. In the Launch Permission dialog box, click Add.10. In the Select Users or Gr

Strany 117 - Power Meter and VFL

Preparing for AutomationFTB-500 193Configuring DCOM Access to Your Unit12. Confirm the newly added user has Remote Launch and Activation permission as

Strany 118 - 108 FTB-500

Preparing for Automation194 FTB-500Configuring DCOM Access to Your UnitCustomizing the Specific Security ParametersOnce you have defined the general s

Strany 119

Preparing for AutomationFTB-500 195Configuring DCOM Access to Your Unit4. In the Authentication Level list, select Default.

Strany 120

Preparing for Automation196 FTB-500Configuring DCOM Access to Your Unit5. In the EXFO KernosHost Properties dialog box, click the Security tab.6. Unde

Strany 121 - FTB-500 111

Preparing for AutomationFTB-500 197Configuring DCOM Access to Your Unit8. In the Select Users or Groups dialog box, under Enter the object names to se

Strany 122

Preparing for Automation198 FTB-500Configuring DCOM Access to Your Unit10. In the Launch Permission dialog box, select a user. 11. To allow this user

Strany 123

Preparing for AutomationFTB-500 199Configuring DCOM Access to Your Unit14. In the EXFO KernosHost Properties dialog box, click the Security tab.15. Un

Strany 124 - OK to exit the window

Introducing the FTB-500FTB-500 11ConventionsConventionsBefore using the product described in this guide, you should understand the following conventio

Strany 125 - Wavelength list

Preparing for Automation200 FTB-500Configuring DCOM Access to Your Unit17. In the Select Users or Groups dialog box, under Enter the object names to s

Strany 126 - Measuring Power or Loss

Preparing for AutomationFTB-500 201Configuring DCOM Access to Your Unit21. Repeat steps 19 and 20 for each newly added user.Note: You can also deny co

Strany 127

Preparing for Automation202 FTB-500Configuring DCOM Access to Your UnitEnabling DCOM on Client ComputerIf you want to subscribe to EXFO IcSCPIAccess C

Strany 128 - 118 FTB-500

Preparing for AutomationFTB-500 203Configuring DCOM Access to Your Unit4. In the Component Services dialog box, select: Console Root> Component Ser

Strany 129 - Opening Results Files

Preparing for Automation204 FTB-500Configuring DCOM Access to Your Unit5. Right-click My Computer, and then select Properties.6. In the My Computer Pr

Strany 130 - 120 FTB-500

Preparing for AutomationFTB-500 205Configuring DCOM Access to Your Unit11. Click the COM Security tab and, under Access Permissions, click Edit Limits

Strany 131 - FTB-500 121

Preparing for Automation206 FTB-500Configuring DCOM Access to Your UnitDisabling DCOM Access to Your FTB-500If you no longer want client computers to

Strany 132 - 122 FTB-500

Preparing for AutomationFTB-500 207Configuring DCOM Access to Your Unit5. In the EXFO KernosHost Properties dialog box, click the Security tab.6. Unde

Strany 133 - Printing Results Reports

Preparing for Automation208 FTB-500Preparing to Control Modules with a Dedicated ApplicationPreparing to Control Modules with a Dedicated ApplicationS

Strany 134 - 124 FTB-500

Preparing for AutomationFTB-500 209Preparing to Control Modules with a Dedicated ApplicationTo activate or deactivate remote control:1. Select the Too

Strany 136 - 126 FTB-500

Preparing for Automation210 FTB-500Preparing to Control Modules with a Dedicated Application3. From the Remote Control Configuration window you will s

Strany 137 - FTB-500 127

Preparing for AutomationFTB-500 211Preparing to Control Modules with a Dedicated Application5. Under Description, type a relevant description (test in

Strany 139 - FTB-500 129

FTB-500 21311 Using FTB Products in an Automated Test EnvironmentEXFO supplies commands that follow the guidelines determined by the SCPI consortium a

Strany 140

Using FTB Products in an Automated Test Environment214 FTB-500Managing the States of Your FTB-500Managing the States of Your FTB-500Your FTB-500 can b

Strany 141 - 8 Managing Data

Using FTB Products in an Automated Test EnvironmentFTB-500 215Managing the States of Your FTB-500The following diagram shows the possible transitions

Strany 142 - 132 FTB-500

Using FTB Products in an Automated Test Environment216 FTB-500Standard Status Data StructureStandard Status Data StructureEach device that is physical

Strany 143

Using FTB Products in an Automated Test EnvironmentFTB-500 217Standard Status Data StructureThe following table presents a summary of the possible ope

Strany 144 - 134 FTB-500

Using FTB Products in an Automated Test Environment218 FTB-500Standard Status Data StructureThe following table presents a summary of the possible ope

Strany 145 - FTB-500 135

Using FTB Products in an Automated Test EnvironmentFTB-500 219Standard Status Data Structure

Strany 146 - 136 FTB-500

FTB-500 132 Safety InformationWARNINGDo not install or terminate fibers while a light source is active. Never look directly into a live fiber and ensu

Strany 147 - 7a. Tap Browse

Using FTB Products in an Automated Test Environment220 FTB-500SCPI Command StructureSCPI Command StructureThe information presented in this section pr

Strany 148 - 138 FTB-500

Using FTB Products in an Automated Test EnvironmentFTB-500 221SCPI Command StructureThe following table shows elements that are commonly used in the c

Strany 149 - FTB-500 139

Using FTB Products in an Automated Test Environment222 FTB-500SCPI Command Structure<mnemonic> Element used in the construction of certain data

Strany 150 - 140 FTB-500

Using FTB Products in an Automated Test EnvironmentFTB-500 223Consulting Data TypesThere are also several conventions regarding command syntax: Spell

Strany 151 - FTB-500 141

Using FTB Products in an Automated Test Environment224 FTB-500Writing Remote Control CodeWriting Remote Control CodeComplex measurement programs may b

Strany 152 - 4. Tap Network Connections

Using FTB Products in an Automated Test EnvironmentFTB-500 225Writing Remote Control CodeWhen you write code, you must follow these rules on message r

Strany 153

Using FTB Products in an Automated Test Environment226 FTB-500Error Message FormatError Message FormatSystem and device-specific errors are managed by

Strany 154 - 144 FTB-500

Using FTB Products in an Automated Test EnvironmentFTB-500 227Working with EXFO COM ObjectsWorking with EXFO COM ObjectsThe ToolBox CD offers you a de

Strany 155 - FTB-500 145

Using FTB Products in an Automated Test Environment228 FTB-500Working with EXFO LabVIEW DriversWorking with EXFO LabVIEW DriversEXFO provides you with

Strany 156 - 146 FTB-500

Using FTB Products in an Automated Test EnvironmentFTB-500 229Working with EXFO LabVIEW DriversThe following table presents the possible settings for

Strany 157 - 3c. Tap System

Safety Information14 FTB-500Other Safety Symbols on Your UnitOther Safety Symbols on Your UnitOne or more of the following symbols may also appear on

Strany 158 - 148 FTB-500

Using FTB Products in an Automated Test Environment230 FTB-500Using the EXFO Getting Started ApplicationsUsing the EXFO Getting Started ApplicationsOn

Strany 159 - Tree view

Using FTB Products in an Automated Test EnvironmentFTB-500 231Using the EXFO Getting Started ApplicationsOn the Front Panel, you can set communication

Strany 160

Using FTB Products in an Automated Test Environment232 FTB-500Using the EXFO Getting Started ApplicationsThe following figure illustrates the State Ma

Strany 161 - FTB-500 151

Using FTB Products in an Automated Test EnvironmentFTB-500 233Using the EXFO Getting Started ApplicationsThe detail of this sub VI gives precious info

Strany 162

Using FTB Products in an Automated Test Environment234 FTB-500Using the EXFO Getting Started Applications6. When you are finished, select Close to end

Strany 163 - FTB-500 153

Using FTB Products in an Automated Test EnvironmentFTB-500 235Building and Using Custom VIsBuilding and Using Custom VIsEXFO LabVIEW drivers have been

Strany 164

Using FTB Products in an Automated Test Environment236 FTB-500Building and Using Custom VIsWhen you click an icon in the EXFO palette, the correspondi

Strany 165 - TightVNC Client

Using FTB Products in an Automated Test EnvironmentFTB-500 237Building and Using Custom VIsNote: The procedure provided hereafter is for guidance only

Strany 166 - Working with Remote Desktop

Using FTB Products in an Automated Test Environment238 FTB-500Building and Using Custom VIs2c. From the Instrument I/O palette, select Instrument Driv

Strany 167

Using FTB Products in an Automated Test EnvironmentFTB-500 239Building and Using Custom VIs8. Set the required parameters and connect the instrument C

Strany 168 - Accessing Your Unit Remotely

Safety InformationFTB-500 15Laser Safety InformationLaser Safety InformationUnits with Built-In VFLYour instrument is a Class 3R laser product in comp

Strany 169

Using FTB Products in an Automated Test Environment240 FTB-500Building and Using Custom VIs10. When you are finished, add EXIQSBASE_CloseComm.vi to yo

Strany 170

Using FTB Products in an Automated Test EnvironmentFTB-500 241Monitoring Remote CommandsMonitoring Remote CommandsToolBox allows you to monitor remote

Strany 171

Using FTB Products in an Automated Test Environment242 FTB-500Monitoring Remote Commands3. Do one of the following: If monitoring using ActiveX or RS

Strany 172 - 6. Tap Select Remote Users

Using FTB Products in an Automated Test EnvironmentFTB-500 243Monitoring Remote Commands If monitoring using TCP/IP, which provides sending SCPI comm

Strany 173

Using FTB Products in an Automated Test Environment244 FTB-500Monitoring Remote CommandsConnection information is also displayed in a separate tab, id

Strany 174 - 164 FTB-500

FTB-500 24512 MaintenanceTo help ensure long, trouble-free operation: Always inspect fiber-optic connectors before using them and clean them if neces

Strany 175

Maintenance246 FTB-500Cleaning Detector PortsCleaning Detector PortsRegular cleaning of detectors will help maintain measurement accuracy.To clean det

Strany 176 - 166 FTB-500

MaintenanceFTB-500 247Cleaning VFL-Type ConnectorsCleaning VFL-Type ConnectorsVFL-type connectors are fixed on your unit and can be cleaned using a me

Strany 177 - Working With TightVNC

Maintenance248 FTB-500Cleaning the TouchscreenCleaning the TouchscreenClean the touchscreen with a soft, non-abrasive cloth, such as one used for clea

Strany 178 - 168 FTB-500

MaintenanceFTB-500 249Battery Maintenance RecommendationsBattery Maintenance Recommendations To ensure that batteries function or charge properly, ke

Strany 179

Safety Information16 FTB-500Electrical Safety InformationElectrical Safety InformationThe four-slot model uses an external AC/DC adapter connected to

Strany 180 - Computer

Maintenance250 FTB-500Inserting and Removing BatteriesInserting and Removing BatteriesThe FTB-500 can be powered either by batteries or from an approp

Strany 181

MaintenanceFTB-500 251Inserting and Removing Batteries2. Open the battery compartment located on the back panel of the unit by undoing the retaining s

Strany 182 - 172 FTB-500

Maintenance252 FTB-500Verif ying Batter y Status4. Slide the new battery in, using the image below as a guide. It will not go in completely if inserte

Strany 183 - FTB-500 173

MaintenanceFTB-500 253Verifying Battery StatusIf you are using alternating current (AC), the gauge will show an electric plug icon.Tapping the icon wi

Strany 184 - 174 FTB-500

Maintenance254 FTB-500Recalibrating the BatteriesRecalibrating the BatteriesDepending on the way the unit is used, after a while, the charge status ic

Strany 185 - 10 Preparing for Automation

MaintenanceFTB-500 255Recalibrating the Batteries2. Connect your unit to a power outlet using the provided AC adapter/charger or power supply.3. Tap t

Strany 186

Maintenance256 FTB-500Enabling Automatic Windows UpdatesEnabling Automatic Windows UpdatesYou can configure your unit to automatically search and inst

Strany 187 - Preparing for Automation

MaintenanceFTB-500 257Enabling Automatic Windows UpdatesTo enable the automatic updates for Windows applications:1. From the main window, select the T

Strany 188

Maintenance258 FTB-500Enabling Automatic Windows Updates4. Select the update option that better suits your need.5. Tap Apply to confirm the changes, a

Strany 189 - FTB-500 179

MaintenanceFTB-500 259Replacing Fuses (Eight-Slot Model Only)Replacing Fuses (Eight-Slot Model Only)The unit contains two F6.3A L type fuses (5 mm x 2

Strany 190 -  PACKed

Safety InformationFTB-500 17Electrical Safety InformationThe color coding used in the electric cable depends on the cable. New plugs should meet the l

Strany 191 - FTB-500 and starting ToolBox

Maintenance260 FTB-500Recalibrating the Unit5. Make sure the fuses are placed firmly in the holder prior to reinsertion.6. Firmly push the fuse holder

Strany 192 - 182 FTB-500

MaintenanceFTB-500 261Recycling and Disposal (Applies to European Union Only)To help you with calibration follow-up, EXFO provides a special calibrati

Strany 194 - 184 FTB-500

FTB-500 26313 TroubleshootingSolving Common ProblemsBefore calling EXFO’s technical support, you may want to consider the following solutions to probl

Strany 195 -  register callback events

Troubleshooting264 FTB-500Solving Common ProblemsThe USB device I have just installed is not working. There might have been a problem during installa

Strany 196 - 186 FTB-500

TroubleshootingFTB-500 265Solving Common ProblemsThe 3G USB modem key is connected, but you are not able to access the Internet. There is no SIM card

Strany 197

Troubleshooting266 FTB-500Solving Common Problems(...continued) The 3G USB modem key is connected, but you are not able to access the Internet. A pro

Strany 198 - 188 FTB-500

TroubleshootingFTB-500 267Solving Common ProblemsThe GPS USB key is not detected.--- Disconnect the GPS key from your unit, and try connecting it agai

Strany 199 - FTB-500 189

Troubleshooting268 FTB-500Solving Common ProblemsBattery indicator shows only a fraction of the power is left, but the batteries are fully charged.(Yo

Strany 200 - 5. Click OK

TroubleshootingFTB-500 269Solving Common ProblemsMy module does not seem to fit all the way inside the platform and I cannot lock it in place using th

Strany 201 - FTB-500 191

Safety Information18 FTB-500Electrical Safety InformationWARNING Use only the listed and certified AC adapter/charger provided by EXFO with your unit

Strany 202 - 192 FTB-500

Troubleshooting270 FTB-500LED Indicator Color CodesLED Indicator Color CodesThe LED indicators can convey different message depending on their colors

Strany 203 - FTB-500 193

TroubleshootingFTB-500 271LED Indicator Color CodesLED Color and Status MessageBattery (external power not connected) Not lit Yellow Yellow, blinki

Strany 204 - 194 FTB-500

Troubleshooting272 FTB-500Restoring Your Unit to Normal OperationRestoring Your Unit to Normal OperationYour FTB-500 is set to start using the standar

Strany 205

TroubleshootingFTB-500 273Restoring Your Unit to Normal OperationNote: You may find useful to connect a keyboard and a mouse to your unit before using

Strany 206

Troubleshooting274 FTB-500Restoring Your Unit to Normal OperationTo restore the system partition:1. Turn on the FTB-500.2. While the system is display

Strany 207 - 9. Click OK

TroubleshootingFTB-500 275Restoring Your Unit to Normal Operation4. From the main window, select Restore system partition from an image, then tap Next

Strany 208 - 198 FTB-500

Troubleshooting276 FTB-500Restoring Your Unit to Normal Operation6. Tap Next to proceed to the next step.7. Tap Next to start the restoration process.

Strany 209

TroubleshootingFTB-500 277Restoring Your Unit to Normal OperationTo retrieve data from the D drive:1. Turn on the FTB-500.2. While the system is displ

Strany 210 - 200 FTB-500

Troubleshooting278 FTB-500Restoring Your Unit to Normal Operation5. Select the files to back up. A green check mark indicates a selection of the entir

Strany 211 - FTB-500 201

TroubleshootingFTB-500 279Restoring Your Unit to Normal Operation7. Select the USB device onto which you want to save the data from the list of availa

Strany 212 - 202 FTB-500

Safety InformationFTB-500 19Electrical Safety InformationMaximum operation altitude  2000 m (6562 ft) (unit connected to external power supply) 5000

Strany 213

Troubleshooting280 FTB-500Restoring Your Unit to Normal OperationTo verify disk integrity:1. Turn on the FTB-500.2. While the system is displaying the

Strany 214 - 204 FTB-500

TroubleshootingFTB-500 281Restoring Your Unit to Normal Operation5. Tap Next to start the disk analysis.Once the analysis is complete, you can view a

Strany 215 - FTB-500 205

Troubleshooting282 FTB-500Accessing Online HelpAccessing Online HelpYou can either access the online help for the platform itself, or obtain more info

Strany 216 - 206 FTB-500

TroubleshootingFTB-500 283Accessing Online HelpViewing Information about the ModulesYou can obtain more information on the modules that are currently

Strany 217 - FTB-500 207

Troubleshooting284 FTB-500Contacting the Technical Support GroupContacting the Technical Support GroupTo obtain after-sales service or technical suppo

Strany 218

TroubleshootingFTB-500 285Viewing System InformationViewing System InformationThe System Information function tab contains important information on yo

Strany 219 - 1. Select the Tools tab

Troubleshooting286 FTB-500Viewing System Information2. Select the About tab to view information on your unit.

Strany 220 - 210 FTB-500

TroubleshootingFTB-500 287Viewing System InformationViewing Platform-Related InformationYou might need information specific to the platform, such as c

Strany 221 - FTB-500 211

Troubleshooting288 FTB-500Transportation2. Select the Platform tab.TransportationMaintain a temperature range within specifications when transporting

Strany 222

FTB-500 28914 WarrantyGeneral InformationEXFO Inc. (EXFO) warrants this equipment against defects in material and workmanship for a period of one year

Strany 223 - Automated Test Environment

FTB-500 iiiEnd-User License AgreementYou have acquired a device ("DEVICE") that includes software licensed by EXFO Inc. (EXFO) from an affil

Strany 224

Safety Information20 FTB-500Electrical Safety InformationCAUTIONUse of voltages higher than those indicated on the label affixed to your unit may dama

Strany 225

Warranty290 FTB-500LiabilityLiabilityEXFO shall not be liable for damages resulting from the use of the product, nor shall be responsible for any fail

Strany 226 - ESR and ESE

WarrantyFTB-500 291ExclusionsExclusionsEXFO reserves the right to make changes in the design or construction of any of its products at any time withou

Strany 227 - STB and SRE

Warranty292 FTB-500Service and RepairsService and RepairsEXFO commits to providing product service and repair for five years following the date of pur

Strany 228

WarrantyFTB-500 293EXFO Service Centers WorldwideEXFO Service Centers WorldwideIf your product requires servicing, contact your nearest authorized ser

Strany 230 - SCPI Command Structure

FTB-500 295A Technical SpecificationsIMPORTANTThe following technical specifications can change without notice. The information presented in this sect

Strany 231 - Item Meaning

Technical Specifications296 FTB-500Notesa. All specifications valid at 23 °C (73 °F).b. Standard recharge time is 4 h. Recharge temperature: 0 °C t

Strany 232 - 222 FTB-500

FTB-500 297BData TypesThe following section provides an overview of the most common data types that may appear in EXFO’s documentation on commands and

Strany 233 - Consulting Data Types

Data Types298 FTB-500Applicable Data Types for Input—IEEE 488.2Applicable Data Types for Input—IEEE 488.2 <PROGRAM MESSAGE TERMINATOR>In the di

Strany 234 - Writing Remote Control Code

Data TypesFTB-500 299Applicable Data Types for Input—IEEE 488.2 <CHARACTER PROGRAM DATA>This data type will be used to send short mnemonics whe

Strany 235 - FTB-500 225

FTB-500 213 Getting Started with Your FTB-500Inserting and Removing Test ModulesTo insert a module into the FTB-500:1. Exit ToolBox and turn off your

Strany 236 - Error Message Format

Data Types300 FTB-500Applicable Data Types for Input—IEEE 488.2 <NON-DECIMAL NUMERIC PROGRAM DATA>This data type will be used for integer repre

Strany 237 - Working with EXFO COM Objects

Data TypesFTB-500 301Applicable Data Types for Input—IEEE 488.2Examples: #Q1234567, #q1275, #q07Examples: #B10010111, #b10110, #b1100# Q/q21034567# B/

Strany 238

Data Types302 FTB-500Applicable Data Types for Input—IEEE 488.2 <STRING PROGRAM DATA>This data type will be used for strings containing 7-bit A

Strany 239 - FTB-500 229

Data TypesFTB-500 303Applicable Data Types for Input—IEEE 488.2 <ARBITRARY BLOCK PROGRAM DATA>This data type is used to send blocks of arbitrar

Strany 240 - 230 FTB-500

Data Types304 FTB-500Applicable Data Types for Input—IEEE 488.2 <SUFFIX PROGRAM DATA>This data type is used when units and multipliers have to

Strany 241

Data TypesFTB-500 305Applicable Data Types for Input—IEEE 488.2The following table illustrates the possible forms for <suffix mult.>:Name Value

Strany 242 - 232 FTB-500

Data Types306 FTB-500Applicable Data Types for Input—IEEE 488.2The table below gives the possible forms for <suffix unit>: Reference Unit Suffix

Strany 243 - Instrument driver VI

Data TypesFTB-500 307Applicable Data Types for Output —IEEE 488.2Applicable Data Types for Output —IEEE 488.2 <RESPONSE MESSAGE TERMINATOR>In t

Strany 244

Data Types308 FTB-500Applicable Data Types for Output —IEEE 488.2 <NR1 NUMERIC RESPONSE DATA> (or <NR1>)This data type will be used by a

Strany 245 - Building and Using Custom VIs

Data TypesFTB-500 309Applicable Data Types for Output —IEEE 488.2 <NR3 NUMERIC RESPONSE DATA> (or <NR3>)This data type will be used by a

Strany 246 - 236 FTB-500

Getting Started with Your FTB-50022 FTB-500Inserting and Removing Test Modules (4-slot model) identification sticker must be on left side and retaini

Strany 247

Data Types310 FTB-500Applicable Data Types for Output —IEEE 488.2 Special Numeric Values Received on OutputIn some cases, an instrument may send valu

Strany 248 - 238 FTB-500

Data TypesFTB-500 311Applicable Data Types for Output —IEEE 488.2 <HEXADECIMAL NUMERIC RESPONSE DATA>This data type will be used by a device to

Strany 249

Data Types312 FTB-500Applicable Data Types for Output —IEEE 488.2 <OCTAL NUMERIC RESPONSE DATA>This data type will be used by a device to retur

Strany 250 - 240 FTB-500

Data TypesFTB-500 313Applicable Data Types for Output —IEEE 488.2 <BINARY NUMERIC RESPONSE DATA>This data type will be used by a device to retu

Strany 251 - Monitoring Remote Commands

Data Types314 FTB-500Applicable Data Types for Output —IEEE 488.2 <DEFINITE LENGTH ARBITRARY BLOCK RESPONSE DATA>This data type is used by a de

Strany 252 - 242 FTB-500

Data TypesFTB-500 315Applicable Data Types for Output —IEEE 488.2 <INDEFINITE LENGTH ARBITRARY BLOCK RESPONSE DATA>This data type is used by a

Strany 253

Data Types316 FTB-500Applicable Data Types for Output —IEEE 488.2 <SUFFIX RESPONSE DATA>This data type is used by a device to return units and

Strany 254 - 244 FTB-500

Data TypesFTB-500 317Applicable Data Types for Input—SCPIApplicable Data Types for Input—SCPISCPI data types include the IEEE 488.2 data types (see Ap

Strany 255 - 12 Maintenance

Data Types318 FTB-500Special Numeric Values Received on OutputSpecial Numeric Values Received on OutputIt is possible that an instrument returns unusu

Strany 256

FTB-500 319C IEEE 488.2 and Specific Command ReferenceThis chapter presents detailed information about the commands and queries supplied with your FTB

Strany 257 - Cleaning VFL-Type Connectors

Getting Started with Your FTB-500FTB-500 23Inserting and Removing Test ModulesNote: If you are using larger or heavier modules, place them near the bo

Strany 258 - Cleaning the Touchscreen

IEEE 488.2 and Specific Command Reference320 FTB-500IEEE 488.2 Required CommandsIEEE 488.2 Required Commands*CLSDescription The *CLS command clears th

Strany 259

IEEE 488.2 and Specific Command ReferenceFTB-500 321IEEE 488.2 Required Commands*ESEDescription The *ESE command sets the Standard Event Status Enable

Strany 260

IEEE 488.2 and Specific Command Reference322 FTB-500IEEE 488.2 Required Commands The table below shows the contents of this register.A value of 1 in t

Strany 261 - Maintenance

IEEE 488.2 and Specific Command ReferenceFTB-500 323IEEE 488.2 Required Commands*ESE?Description With the *ESE? query you can determine the current co

Strany 262 - (-) T D C (+)

IEEE 488.2 and Specific Command Reference324 FTB-500IEEE 488.2 Required CommandsResponse(s) RegisterValue: The response data syntax for <RegisterVa

Strany 263

IEEE 488.2 and Specific Command ReferenceFTB-500 325IEEE 488.2 Required Commands*ESR?Description With the *ESR? query you can determine the current co

Strany 264

IEEE 488.2 and Specific Command Reference326 FTB-500IEEE 488.2 Required CommandsResponse(s) RegisterValue: The response data syntax for <RegisterVa

Strany 265 - Recalibrating the Batteries

IEEE 488.2 and Specific Command ReferenceFTB-500 327IEEE 488.2 Required Commands*IDN?Description The intent of the *IDN? query is for the unique ident

Strany 266

IEEE 488.2 and Specific Command Reference328 FTB-500IEEE 488.2 Required CommandsField 3 (Serial number): ASCII character (0 if not available)Field 4

Strany 267 - 3. Tap Automatic Updates

IEEE 488.2 and Specific Command ReferenceFTB-500 329IEEE 488.2 Required Commands*OPCDescription The *OPC command makes synchronization between the ins

Strany 268 - Control Panel window

Getting Started with Your FTB-50024 FTB-500Inserting and Removing Test Modules7. While applying slight pressure to the module, turn the retaining scre

Strany 269 - Fuse holder

IEEE 488.2 and Specific Command Reference330 FTB-500IEEE 488.2 Required Commands*OPC?Description The *OPC? query makes possible the synchronization be

Strany 270 - Recalibrating the Unit

IEEE 488.2 and Specific Command ReferenceFTB-500 331IEEE 488.2 Required Commands*RSTDescription The *RST command performs a device reset. This command

Strany 271 - Recycling and Disposal

IEEE 488.2 and Specific Command Reference332 FTB-500IEEE 488.2 Required Commands*SREDescription The *SRE command sets the Service Request Enable Regis

Strany 272

IEEE 488.2 and Specific Command ReferenceFTB-500 333IEEE 488.2 Required CommandsSee the contents of this register below.A bit value of zero shall indi

Strany 273 - 13 Troubleshooting

IEEE 488.2 and Specific Command Reference334 FTB-500IEEE 488.2 Required Commands*SRE?Description With the *SRE? query you can determine the current co

Strany 274

IEEE 488.2 and Specific Command ReferenceFTB-500 335IEEE 488.2 Required CommandsResponse(s) RegisterValue: The response data syntax for <RegisterVa

Strany 275 - FTB-500 265

IEEE 488.2 and Specific Command Reference336 FTB-500IEEE 488.2 Required Commands*STB?Description With the *STB? query you can read the status byte and

Strany 276

IEEE 488.2 and Specific Command ReferenceFTB-500 337IEEE 488.2 Required CommandsResponse(s) RegisterValue: The response data syntax for <RegisterVa

Strany 277 - FTB-500 267

IEEE 488.2 and Specific Command Reference338 FTB-500IEEE 488.2 Required Commands*TST?Description The *TST? query causes an internal self-test and plac

Strany 278 -  Change the batteries

IEEE 488.2 and Specific Command ReferenceFTB-500 339IEEE 488.2 Required Commands*WAIDescription The *WAI command shall prevent the device from executi

Strany 279

Getting Started with Your FTB-500FTB-500 25Inserting and Removing Test Modules8. If you are using a larger or heavier module, use a front module lock

Strany 280 - LED Indicator Color Codes

IEEE 488.2 and Specific Command Reference340 FTB-500Specific Commands—Quick ReferenceSpecific Commands—Quick ReferenceThe table below contains a summa

Strany 281 - FTB-500 271

IEEE 488.2 and Specific Command ReferenceFTB-500 341Specific CommandsSpecific Commands:FORMat[:DATA]Description The FORMat[:DATA] command selects the

Strany 282

IEEE 488.2 and Specific Command Reference342 FTB-500Specific CommandsIn ASCii format, the numeric data is transferred to ASCii bytes in <NR1 NUMERI

Strany 283

IEEE 488.2 and Specific Command ReferenceFTB-500 343Specific Commands:FORMat[:DATA]?Description The FORMat[:DATA]? query returns the data format and t

Strany 284 - 274 FTB-500

IEEE 488.2 and Specific Command Reference344 FTB-500Specific CommandsWhen the data is returned in ASCII, the <Length> is the number of significa

Strany 285 - FTB-500 275

IEEE 488.2 and Specific Command ReferenceFTB-500 345Specific Commands:INSTrument:CATalog?Description The INSTrument:CATalog? query returns a comma-sep

Strany 286 - Troubleshooting

IEEE 488.2 and Specific Command Reference346 FTB-500Specific Commands:INSTrument:CATalog:FULL?Description The INSTrument:CATalog:FULL? returns a list

Strany 287 - FTB-500 277

IEEE 488.2 and Specific Command ReferenceFTB-500 347Specific Commands:SYSTem:DATEDescription The SYSTem:DATE command is used to set the device's

Strany 288 - 278 FTB-500

IEEE 488.2 and Specific Command Reference348 FTB-500Specific Commands Day: The program data syntax for <Day> is defined as a <DECIMAL NUMERI

Strany 289 - FTB-500 279

IEEE 488.2 and Specific Command ReferenceFTB-500 349Specific Commands:SYSTem:DATE?Description The SYSTem:DATE query returns the instrument's inte

Strany 290 - 280 FTB-500

Getting Started with Your FTB-50026 FTB-500Inserting and Removing Test ModulesTo remove a module from the FTB-500:1. Exit ToolBox and turn off your un

Strany 291 - FTB-500 281

IEEE 488.2 and Specific Command Reference350 FTB-500Specific CommandsResponse(s)  Year: The response data syntax for <Year> is defined as a <

Strany 292 - Accessing Online Help

IEEE 488.2 and Specific Command ReferenceFTB-500 351Specific Commands:SYSTem:ERRor[:NEXT]?Description The SYSTem:ERRor[:NEXT]? queries the error/event

Strany 293

IEEE 488.2 and Specific Command Reference352 FTB-500Specific CommandsThe <Description[,Info]> parameter of the full response is a quoted string

Strany 294 - 284 FTB-500

IEEE 488.2 and Specific Command ReferenceFTB-500 353Specific Commands:SYSTem:TIMEDescription This device has an internal clock and implements the SYST

Strany 295 - Viewing System Information

IEEE 488.2 and Specific Command Reference354 FTB-500Specific Commands Seconds: The program data syntax for <Seconds> is defined as a <DECIMA

Strany 296

IEEE 488.2 and Specific Command ReferenceFTB-500 355Specific Commands:SYSTem:TIME?Description This device has an internal clock and implements the SYS

Strany 297 - To access the Platform tab:

IEEE 488.2 and Specific Command Reference356 FTB-500Specific CommandsResponse(s)  Hour: The response data syntax for <Hour> is defined as a <

Strany 298 - Transportation

IEEE 488.2 and Specific Command ReferenceFTB-500 357Specific Commands:SYSTem:VERSion?Description The SYSTem:VERSion? query returns a value correspondi

Strany 300 - Liability

FTB-500 359D SCPI-Based ErrorsError NumberDescription Probable Cause–100 “Command error” This is the generic syntax error for devices that cannot dete

Strany 301

Getting Started with Your FTB-500FTB-500 27Inserting and Removing Test Modules5. Hold the module by its sides or by the handle (NOT by the connector)

Strany 302 - Service and Repairs

SCPI-Based Errors360 FTB-500–110 “Command header error”An error was detected in the header. This error message should be used when the device cannot d

Strany 303 - FTB-500 293

SCPI-Based ErrorsFTB-500 361–123 “Exponent too large” The magnitude of the exponent was larger than 32000 (see IEEE 488.2, 7.7.2.4.1).–124 “Too many d

Strany 304

SCPI-Based Errors362 FTB-500–150 “String data error” This error, as well as errors –151 through –159, are generated when parsing a string data element

Strany 305 - A Technical Specifications

SCPI-Based ErrorsFTB-500 363–180 “Macro error” This error, as well as errors –181 through –189, are generated when defining a macro or executing a mac

Strany 306 - Technical Specifications

SCPI-Based Errors364 FTB-500–210 “Trigger error” -----–211 “Trigger ignored” Indicates that a GET, *TRG, or triggering signal was received and recogni

Strany 307 - BData Types

SCPI-Based ErrorsFTB-500 365–222 “Data out of range” Indicates that a legal program data element was parsed but could not be executed because the inte

Strany 308 - <wsp> NL END^

SCPI-Based Errors366 FTB-500–233 “Invalid version” Indicates that a legal program data element was parsed but could not be executed because the versio

Strany 309 - FTB-500 299

SCPI-Based ErrorsFTB-500 367–253 “Corrupt media” Indicates that a legal program command or query could not be executed because of corrupt media; for e

Strany 310 - 300 FTB-500

SCPI-Based Errors368 FTB-500–260 “Expression error” [Indicates that a expression program data element related error occurred. This error message shoul

Strany 311 - Data Types

SCPI-Based ErrorsFTB-500 369–275 “Macro definition too long”[Indicates that a syntactically legal macro program data sequence could not be executed be

Strany 312 -  <STRING PROGRAM DATA>

Getting Started with Your FTB-50028 FTB-500Turning On the FTB-500Turning On the FTB-500To turn on the FTB-500: Hold down the On/Off button on the fron

Strany 313 - FTB-500 303

SCPI-Based Errors370 FTB-500–284 “Program currently running”[Certain operations dealing with programs may be illegal while the program is running; for

Strany 314 - <digit>

SCPI-Based ErrorsFTB-500 371–312 “PUD memory lost” [Indicates that the protected user data saved by the *PUD command has been lost.]–313 “Calibration

Strany 315 - Name Value Mnemonic

SCPI-Based Errors372 FTB-500–363 “Input buffer overrun” [Software or hardware input buffer on serial port overflows with data caused by improper or no

Strany 316 - Reference Unit Suffix Unit

SCPI-Based ErrorsFTB-500 373–700 “Request control” [The instrument requested to become the active IEEE 488.1 controller-in-charge.]–800 “Operation com

Strany 318 - <digit> <digit>

FTB-500 375E COM Properties and EventsThe FTB-500 also provides objects based on Microsoft Component Object Model (COM). COM defines a common way to a

Strany 319

COM Properties and Events376 FTB-500ActiveX (COM/DCOM)—Quick ReferenceActiveX (COM/DCOM)—Quick ReferenceThe following diagram illustrates the differen

Strany 320 - 310 FTB-500

COM Properties and EventsFTB-500 377PropertiesPropertiesWriteDescription With this method you can send a program message (single command or compound o

Strany 321

COM Properties and Events378 FTB-500PropertiesWriteBinaryDescription With this method you can send a program message (single command or compound of co

Strany 322

COM Properties and EventsFTB-500 379PropertiesReadDescription With this method you can retrieve all the data from the device output queue in a UNICODE

Strany 323 - ">"

Getting Started with Your FTB-500FTB-500 29Turning On the FTB-500Use this window to start single-module applications. The applications will change dep

Strany 324 - 314 FTB-500

COM Properties and Events380 FTB-500PropertiesReadBinaryDescription With this method you can retrieve data from the device output queue in a binary fo

Strany 325 - TERMINATOR>

COM Properties and EventsFTB-500 381PropertiesFor example, if you receive this response (here, values are expressed in decimal instead of binary for e

Strany 326 - 316 FTB-500

COM Properties and Events382 FTB-500PropertiesDeviceClearDescription This method performs a Device Clear operation as specified in the IEEE 488.1 stan

Strany 327 - FTB-500 317

COM Properties and EventsFTB-500 383PropertiesLockoutStateDescription This property returns or sets the device’s lockout state.Syntax object.LockoutSt

Strany 328 - 488.2 on page 307

COM Properties and Events384 FTB-500EventsEventsRequestServiceDescription This event is triggered whenever the device causes a Service Request (SRQ).P

Strany 329 - Command Reference

IndexFTB-500 385Index3G USB modem, using ... 97AAbout tab... 285AC require

Strany 330 - IEEE 488.2 Required Commands

Index386 FTB-500changingbacklight level... 54batteries ... 250communic

Strany 331

IndexFTB-500 387descriptionfunction buttons... 9LED panel... 8detecti

Strany 332 - Bit Weight Meaning

Index388 FTB-500interface, changing language... 69Internet connection... 96, 97KKensington lock...

Strany 333

IndexFTB-500 389on-screen keyboard... 56opening user guides... 94operation language

Strany 334 - 324 FTB-500

iv FTB-500 Internet Gaming/Update Features. If the SOFTWARE provides, and you choose to utilize, the Internet gaming or update features within the SO

Strany 335

Getting Started with Your FTB-50030 FTB-500Turning Off the FTB-500Turning Off the FTB-500There are several ways to turn off the unit, including the fo

Strany 336 - 326 FTB-500

Index390 FTB-500referencemode ... 115values, setting... 115zero pow

Strany 337

IndexFTB-500 391shutdown modes ... 30softwareaccessing ... 39exiting

Strany 338 - 328 FTB-500

Index392 FTB-500Uunitback and bottom supports ... 49disconnecting ... 16installing...

Strany 339

NOTICE抩⛙CHINESE REGULATION ON RESTRICTION OF HAZARDOUS SUBSTANCES₼⦌␂ℝ☀⹂䓸德棟Ⓟ䤓屓⸩NAMES AND CONTENTS OF THE TOXIC OR HAZARDOUS SUBSTANCES OR ELEMENTS CONT

Strany 340 - 330 FTB-500

MARKING REQUIREMENTS㪖㽷尐㻑Productℶ❐Environmental protection use period (years)䘾⬒≬㔳∎䞷㦮棟 ( ㄃ )Logo㪖㉦This Exfo product㦻 EXFO ℶ❐10Batterya䟄㻯aa. If applicabl

Strany 341

www.EXFO.com · [email protected]/N: 1065807CORPORATE HEADQUARTERS 400 Godin Avenue Quebec (Quebec) G1M 2K2 CANADATel.: 1 418 683-0211 · Fax: 1 418 683-

Strany 342 - 332 FTB-500

Getting Started with Your FTB-500FTB-500 31Turning Off the FTB-500To turn off the unit:1. Press and hold the On/Off button. OROn the Windows taskbar,

Strany 343

Getting Started with Your FTB-50032 FTB-500Turning Off the FTB-5004. Select the Advanced tab.5. From the When I press the power button on my computer

Strany 344 - 334 FTB-500

Getting Started with Your FTB-500FTB-500 33Turning Off the FTB-500To configure your unit to automatically restart after AC power comes back:1. From th

Strany 345

Getting Started with Your FTB-50034 FTB-500Grounding Your FTB-500Grounding Your FTB-500When you perform an outside plant test with modules such as the

Strany 346 - 336 FTB-500

Getting Started with Your FTB-500FTB-500 35Securing your FTB-500 Using the Kensington LockSecuring your FTB-500 Using the Kensington LockYour FTB-500

Strany 347

Getting Started with Your FTB-50036 FTB-500Installing or Upgrading the ApplicationsInstalling or Upgrading the ApplicationsAll the necessary applicati

Strany 348 - 338 FTB-500

Getting Started with Your FTB-500FTB-500 37Installing or Upgrading the ApplicationsFor the installation or upgrade, you will need: an FTB-500 unit a

Strany 349

Getting Started with Your FTB-50038 FTB-500Installing or Upgrading the ApplicationsTo install or upgrade the applications:1. If necessary, retrieve th

Strany 350 - 340 FTB-500

Getting Started with Your FTB-500FTB-500 39Accessing and Exiting ToolBoxAccessing and Exiting ToolBox Your FTB-500 comes out of the factory set to sta

Strany 351 - Specific Commands

FTB-500 vContentsCertification Information ...x1

Strany 352 - :FORMat[:DATA]

Getting Started with Your FTB-50040 FTB-500Starting Module ApplicationsStarting Module ApplicationsYour modules can be configured and controlled form

Strany 353 - :FORMat[:DATA]?

Getting Started with Your FTB-500FTB-500 41Installing EXFO LabVIEW DriversInstalling EXFO LabVIEW DriversBefore being able to work with EXFO LabVIEW d

Strany 354

Getting Started with Your FTB-50042 FTB-500Activating Software OptionsActivating Software OptionsThe software options purchased at the same time as yo

Strany 355 - :INSTrument:CATalog?

Getting Started with Your FTB-500FTB-500 43Activating Software OptionsTo activate the options for your unit:1. Connect a USB memory key to one of the

Strany 356 - :INSTrument:CATalog:FULL?

Getting Started with Your FTB-50044 FTB-500Activating Software Options5. In the Platform Options tab, use the Browse button to locate the key file tha

Strany 357 - :SYSTem:DATE

Getting Started with Your FTB-500FTB-500 45Activating Software OptionsTo activate software options for your module:1. Connect a USB memory key to one

Strany 358

Getting Started with Your FTB-50046 FTB-500Activating Software Options5. In the Module Options tab, use the Browse button to locate the key file that

Strany 359 - :SYSTem:DATE?

Getting Started with Your FTB-500FTB-500 47Installing Third-Party Software on Your FTB-500Installing Third-Party Software on Your FTB-500Since your FT

Strany 361 - :SYSTem:ERRor[:NEXT]?

FTB-500 494 Setting Up Your FTB-500Positioning Your UnitYou can change the orientation of your unit with the bottom or back supports.To position the u

Strany 362

vi FTB-5004 Setting Up Your FTB-500 ...49Positioning Your Unit ...

Strany 363 - :SYSTem:TIME

Setting Up Your FTB-50050 FTB-500Installing a MonitorInstalling a MonitorAlthough the FTB-500 is equipped with a top-of-the line LCD, you might want t

Strany 364

Setting Up Your FTB-500FTB-500 51Calibrating the TouchscreenCalibrating the TouchscreenThe touchscreen simplifies and accelerates testing procedures b

Strany 365 - :SYSTem:TIME?

Setting Up Your FTB-50052 FTB-500Calibrating the TouchscreenTo calibrate the touchscreen:1. Select the Tools tab.2. Select Touch Screen Calibration.3.

Strany 366

Setting Up Your FTB-500FTB-500 53Adjusting the Monitor SettingsAdjusting the Monitor SettingsDifferent work environments call for different monitor se

Strany 367 - :SYSTem:VERSion?

Setting Up Your FTB-50054 FTB-500Changing the Backlight LevelChanging the Backlight LevelThe backlight has five different brightness levels.To change

Strany 368

Setting Up Your FTB-500FTB-500 55Installing a Hardware KeyboardInstalling a Hardware KeyboardWhen you are required to enter alphanumeric data, an on-s

Strany 369 - D SCPI-Based Errors

Setting Up Your FTB-50056 FTB-500Using the On-Screen (Virtual) KeyboardUsing the On-Screen (Virtual) KeyboardYour unit is equipped with an on-screen k

Strany 370 - Description Probable Cause

Setting Up Your FTB-500FTB-500 57Using the Module On-Screen (Virtual) KeyboardTo activate the module on-screen keyboard:1. Select the Tools tab, then

Strany 371

Setting Up Your FTB-50058 FTB-500Customizing the On-Screen KeyboardCustomizing the On-Screen KeyboardYou can customize the appearance and behavior of

Strany 372 - 362 FTB-500

Setting Up Your FTB-500FTB-500 59Right-Clicking with the TouchscreenRight-Clicking with the TouchscreenIf you are used to work with a mouse, you may f

Strany 373

FTB-500 vii6 Using the Optional Built-In Power Meter and VFL ... 107Accessing the Built-In Power Meter ...

Strany 374 - 364 FTB-500

Setting Up Your FTB-50060 FTB-500Installing a Pointing DeviceInstalling a Pointing DeviceA touchscreen offers many advantages when working in applicat

Strany 375

Setting Up Your FTB-500FTB-500 61Installing a Headset or SpeakersInstalling a Headset or SpeakersThe FTB-500 comes with an internal speaker for audibl

Strany 376 - 366 FTB-500

Setting Up Your FTB-50062 FTB-500Installing a MicrophoneInstalling a MicrophoneOn top of being a multitasking test platform, the FTB-500 is a portable

Strany 377

Setting Up Your FTB-500FTB-500 63Installing a PrinterInstalling a PrinterIf you need to print reports directly from your FTB-500, you can install an e

Strany 378 - 368 FTB-500

Setting Up Your FTB-50064 FTB-500Installing an Express CardInstalling an Express CardThe Express card slot found in the FTB-500 supports 34-mm format

Strany 379

Setting Up Your FTB-500FTB-500 65Automating Application StartupAutomating Application StartupYou can have selected applications automatically start up

Strany 380 - 370 FTB-500

Setting Up Your FTB-50066 FTB-500Automating Application Startup2. Select the Application Startup tab.3. Select the items you want to start at startup

Strany 381

Setting Up Your FTB-500FTB-500 67Selecting the FIP Startup ApplicationSelecting the FIP Startup ApplicationYour unit supports both the fiber inspectio

Strany 382 - 372 FTB-500

Setting Up Your FTB-50068 FTB-500Selecting the FIP Startup Application2. Select the Application Startup tab.3. From the When I tap the Probe button li

Strany 383

Setting Up Your FTB-500FTB-500 69Selecting the Language of OperationSelecting the Language of OperationNote: Only administrator-level users can modify

Strany 384

viii FTB-50011 Using FTB Products in an Automated Test Environment ...213Managing the States of Your FTB-500 ...

Strany 385 - E COM Properties and Events

Setting Up Your FTB-50070 FTB-500Selecting the Language of OperationTo select a new interface language:1. From the main window, select the Tools tab.2

Strany 386 - COM Properties and Events

Setting Up Your FTB-500FTB-500 71Selecting the Language of Operation4. Select the Languages tab.5. From the Language used in menus and dialogs list, s

Strany 387 - Properties

Setting Up Your FTB-50072 FTB-500Selecting the Language of Operation6b. Under Language for non-Unicode programs, select the desired language.7. Press

Strany 388

Setting Up Your FTB-500FTB-500 73Selecting the Language of OperationTo add new input languages:1. From the main window, select the Tools tab.2. Tap Co

Strany 389

Setting Up Your FTB-50074 FTB-500Selecting the Language of Operation4. Select the Languages tab.5. Under Text services and input languages, tap Detail

Strany 390 - ReadBinary

Setting Up Your FTB-500FTB-500 75Selecting the Language of Operation6. Under Installed services, tap Add.7. From the Input language list, select the d

Strany 391 - Initialize

Setting Up Your FTB-50076 FTB-500Selecting the Language of OperationTo switch from one of the available input languages to another:1. Tap to display

Strany 392 - RemoteState

Setting Up Your FTB-500FTB-500 77Adjusting the Date, Time and Time ZoneAdjusting the Date, Time and Time ZoneNote: Only administrator-level users can

Strany 393 - StatusByte

Setting Up Your FTB-50078 FTB-500Adjusting the Date, Time and Time Zone3. Tap Date and Time.4. Select the Date & Time tab.5. Modify the settings a

Strany 394 - ReturnToLocal

Setting Up Your FTB-500FTB-500 79Adjusting the Date, Time and Time ZoneTo change the time zone:1. From the main window, select the Tools tab.2. Tap Co

Strany 395 - FTB-500 385

FTB-500 ixA Technical Specifications ... 295B Data Types ...

Strany 396

Setting Up Your FTB-50080 FTB-500Configuring the Power Management OptionsConfiguring the Power Management OptionsNote: Only administrator-level users

Strany 397 - FTB-500 387

Setting Up Your FTB-500FTB-500 81Configuring the Power Management OptionsYou can either modify one of the existing power schemes or create one (based

Strany 398

Setting Up Your FTB-50082 FTB-500Configuring the Power Management OptionsTo select a power scheme:1. From the main window, select the Tools tab.2. Tap

Strany 399 - FTB-500 389

Setting Up Your FTB-500FTB-500 83Configuring the Power Management Options4. From the Power Schemes list, select the desired predefined set of paramete

Strany 400

Setting Up Your FTB-50084 FTB-500Configuring the Power Management OptionsTo modify a power scheme:1. From the main window, select the Tools tab.2. Tap

Strany 401 - FTB-500 391

Setting Up Your FTB-500FTB-500 85Configuring the Power Management Options6. Tap Save As. If you want to modify the existing power scheme, keep the na

Strany 402

Setting Up Your FTB-50086 FTB-500Setting ToolBox OptionsSetting ToolBox OptionsYou can specify how ToolBox behaves when the application is started, mi

Strany 403 - ₼⦌␂ℝ☀⹂䓸德棟Ⓟ䤓屓⸩

Setting Up Your FTB-500FTB-500 87Setting Communication Parameters3. Select one or more option that corresponds to your needs: Hide ToolBox in the sys

Strany 405

FTB-500 895Working with Your UnitAccessing Platform-Related Tools from ToolBoxTools for your platform include remote control settings, battery managem

Komentáře k této Příručce

Žádné komentáře