Exfo FTB-5800 Chromatic Dispersion Analyzer for FTB-400 Uživatelský manuál Strana 1

Procházejte online nebo si stáhněte Uživatelský manuál pro Měřící nástroje Exfo FTB-5800 Chromatic Dispersion Analyzer for FTB-400. EXFO FTB-5800 Chromatic Dispersion Analyzer for FTB-400 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 103
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - ANALYZER

USER GUIDECHROMATIC DISPERSIONANALYZERFTB-5800 for FTB-400NETWORK TESTING

Strany 2

Introducing the FTB-5800 Chromatic Dispersion Analyzer4 FTB-5800ConventionsConventionsBefore using the product described in this manual, you should un

Strany 3 - Contents

Index94 FTB-5800EUI connectors, cleaning ... 72EXFO service centers... 86EXFO universal int

Strany 4

IndexChromatic Dispersion Analyzer 95Pparameters, printer ... 63PDF. see online user guideperformance, optimum ...

Strany 5 - Certification Information

Index96 FTB-5800Ttechnical specifications ... 79, 87technical support ... 80temperature for

Strany 6 - DECLARATION OF CONFORMITY

Printed in Canada (2007-08)www.exfo.com · [email protected]© 2007 EXFO Electro-Optical Engineering Inc. All rights reserved.P/N: 1051071CORPORATEHEADQUA

Strany 7 - 1 Introducing the FTB-5800

Chromatic Dispersion Analyzer 52 Getting Started with Your Chromatic Dispersion AnalyzerInserting and Removing Test Modules To insert a module into th

Strany 8 - Main Features

Getting Started with Your Chromatic Dispersion Analyzer6 FTB-5800Inserting and Removing Test Modules4. Insert the protruding edges of the module into

Strany 9 - Typical Applications

Getting Started with Your Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 7Inserting and Removing Test Modules7. While applying slight pres

Strany 10 - IMPORTANT

Getting Started with Your Chromatic Dispersion Analyzer8 FTB-5800Inserting and Removing Test ModulesTo remove a module from the FTB-400 Universal Test

Strany 11 - Analyzer

Getting Started with Your Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 9Inserting and Removing Test Modules6. Cover empty slots with the

Strany 12 - 6 FTB-5800

Getting Started with Your Chromatic Dispersion Analyzer10 FTB-5800Starting the Chromatic Dispersion Analyzer ApplicationStarting the Chromatic Dispers

Strany 13 - Turn retaining screw knob

Getting Started with Your Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 11Starting the Chromatic Dispersion Analyzer ApplicationThe main

Strany 14 - 8 FTB-5800

Getting Started with Your Chromatic Dispersion Analyzer12 FTB-5800Exiting the ApplicationStatus BarThe status bar, located at the bottom of the main w

Strany 15

Chromatic Dispersion Analyzer 133 Setting Up Your Chromatic Dispersion AnalyzerThe parameters you set will be kept in memory after turning off the FTB

Strany 16 - Application

ii FTB-5800Copyright © 2002–2007 EXFO Electro-Optical Engineering Inc. All rights reserved. No part of this publication may be reproduced, stored in a

Strany 17 - Title Bar

Setting Up Your Chromatic Dispersion Analyzer14 FTB-5800Setting the Wavelength StepSetting the Wavelength StepThe wavelength step corresponds to the i

Strany 18 - Exiting the Application

Setting Up Your Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 15Setting the Wavelength StepTo set the wavelength step using the custom op

Strany 19 - Dispersion Analyzer

Setting Up Your Chromatic Dispersion Analyzer16 FTB-5800Setting the Averaging TimeSetting the Averaging TimeThe averaging time is the time the system

Strany 20 - Setting the Wavelength Step

Setting Up Your Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 17Specifying the Fiber Under TestSpecifying the Fiber Under TestBefore maki

Strany 21

Setting Up Your Chromatic Dispersion Analyzer18 FTB-5800Specifying the Fiber Under TestTo specify the fiber under test: In the Parameters tab, undr Fi

Strany 22 - Setting the Averaging Time

Setting Up Your Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 19Specifying the Fiber Under TestTo modify the distance units:1. On the but

Strany 23

Setting Up Your Chromatic Dispersion Analyzer20 FTB-5800Defining the Automatic Fiber Name FormatDefining the Automatic Fiber Name FormatEach time you

Strany 24 - 18 FTB-5800

Setting Up Your Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 21Defining the Automatic Fiber Name FormatTo define the fiber name format:1

Strany 26 - 20 FTB-5800

Chromatic Dispersion Analyzer 234 Operating Your Chromatic Dispersion AnalyzerInstalling the EXFO Universal Interface (EUI)The EUI fixed baseplate is

Strany 27

ContentsChromatic Dispersion Analyzer iiiContentsCertification Information ...

Strany 28

Operating Your Chromatic Dispersion Analyzer24 FTB-5800Cleaning and Connecting Optical FibersCleaning and Connecting Optical FibersTo connect the fibe

Strany 29 - 4 Operating Your Chromatic

Operating Your Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 25Cleaning and Connecting Optical FibersIMPORTANTThe FTB-5800 module is part

Strany 30

Operating Your Chromatic Dispersion Analyzer26 FTB-5800Selecting the Source TypeSelecting the Source TypeDifferent sources can be used for testing wit

Strany 31

Operating Your Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 27Verifying the Intensity of the SourceVerifying the Intensity of the Source

Strany 32 - Selecting the Source Type

Operating Your Chromatic Dispersion Analyzer28 FTB-5800Performing Reference MeasurementsPerforming Reference MeasurementsIMPORTANTTo ensure the best p

Strany 33

Operating Your Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 29Performing Reference MeasurementsTo take a wavelength reference:Note: If t

Strany 34

Operating Your Chromatic Dispersion Analyzer30 FTB-5800Performing Reference Measurements3. On the Wavelength tab, select the source band corresponding

Strany 35

Operating Your Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 31Performing Reference MeasurementsTo take a chromatic dispersion reference:

Strany 36 - 30 FTB-5800

Operating Your Chromatic Dispersion Analyzer32 FTB-5800Performing Reference Measurements4. On the CD tab, identify the source from which the reference

Strany 37

Operating Your Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 33Applying a Chromatic Dispersion ReferenceApplying a Chromatic Dispersion R

Strany 38 - 32 FTB-5800

Contentsiv FTB-58006 Exporting CD Analyzer Files with the File Export Tool ...65Starting and Exiting the File Export Tool

Strany 39

Operating Your Chromatic Dispersion Analyzer34 FTB-5800Creating a FileCreating a FileEach time you make an acquisition, the results are added to those

Strany 40 - Creating a File

Operating Your Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 35Measuring Chromatic DispersionMeasuring Chromatic DispersionYou can perfor

Strany 41

Operating Your Chromatic Dispersion Analyzer36 FTB-5800Measuring Chromatic Dispersion4. Set the parameters.³ Single acquisition: clear the Multiple Ac

Strany 42 - 36 FTB-5800

Operating Your Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 37Measuring Chromatic Dispersion7. On the button bar, click Start.The Start

Strany 43

Operating Your Chromatic Dispersion Analyzer38 FTB-5800Saving Your ResultsSaving Your ResultsOnce your acquisition is done, you must save your results

Strany 44

Operating Your Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 39Saving Your Results2. Select the folder in which you want to save your dat

Strany 46

Chromatic Dispersion Analyzer 415 Managing ResultsYour FTB-5800 Chromatic Dispersion Analyzer allows you to work with two types of results:³ Newly acq

Strany 47 - 5 Managing Results

Managing Results42 FTB-5800Recalling a Saved FileRecalling a Saved FileIt is possible to reload existing files in .exfocd format. These files can also

Strany 48 - Recalling a Saved File

Managing ResultsChromatic Dispersion Analyzer 43Analyzing Results from the Results GraphAnalyzing Results from the Results GraphThe application presen

Strany 49

Certification InformationChromatic Dispersion Analyzer vCertification InformationF.C.C. InformationElectronic test equipment is exempt from Part 15 co

Strany 50 - 44 FTB-5800

Managing Results44 FTB-5800Analyzing Results from the Results GraphEven if you have acquired your results with a particular type of data fitting, duri

Strany 51

Managing ResultsChromatic Dispersion Analyzer 45Analyzing Results from the Results GraphTo show or hide the fitted lambda zero value:1. On the button

Strany 52 - 46 FTB-5800

Managing Results46 FTB-5800Analyzing Results from the Results GraphTo show or hide the RGD curves and/or RGD values1. On the button bar, click Setup.2

Strany 53 - Managing Results

Managing ResultsChromatic Dispersion Analyzer 47Analyzing Results from the Results GraphTo interpret results using a different type of fit:On the Resu

Strany 54 - 48 FTB-5800

Managing Results48 FTB-5800Analyzing Results from the Results GraphTo position the marker:³ Drag the marker to the point you want to focus on.³ Use th

Strany 55

Managing ResultsChromatic Dispersion Analyzer 49Analyzing Results from the Results GraphTo zoom in on results or zoom out:1. On the Results Graph tab,

Strany 56

Managing Results50 FTB-5800Analyzing Results from the Results GraphTo revert the zoom factor to its default value:1. On the Results Graph tab, click t

Strany 57

Managing ResultsChromatic Dispersion Analyzer 51Analyzing Results from the Results GraphTo have the zoom reset automatically:1. On the button bar, cli

Strany 58

Managing Results52 FTB-5800Analyzing Results from the Results TableAnalyzing Results from the Results TableThe columns presented on the Results Table

Strany 59

Managing ResultsChromatic Dispersion Analyzer 53Analyzing Results from the Results TableWhen applicable, in the dispersion and coefficient of dispersi

Strany 60 - Keeping Track of Acquisitions

Certification Informationvi FTB-5800Application of Council Directive(s):73/23/EEC - The Low Voltage Directive89/336/EEC - The EMC DirectiveManufacture

Strany 61

Managing Results54 FTB-5800Keeping Track of AcquisitionsTo select or deselect points:Select or deselect the corresponding boxes in the first column of

Strany 62 - Establishing Thresholds

Managing ResultsChromatic Dispersion Analyzer 55Keeping Track of AcquisitionsTo display an overall view of the results:Click the Acquisitions tab.To d

Strany 63

Managing Results56 FTB-5800Establishing ThresholdsEstablishing ThresholdsYou can establish two types of thresholds: the dispersion and slope 0 thresho

Strany 64 - 58 FTB-5800

Managing ResultsChromatic Dispersion Analyzer 57Establishing ThresholdsThe Slope 0 Threshold is the slope of the dispersion curve evaluated at the poi

Strany 65 - Documenting Results

Managing Results58 FTB-5800Establishing ThresholdsTo establish your thresholds:1. On the button bar, click Setup.2. Set the thresholds as required.³ I

Strany 66 - 60 FTB-5800

Managing ResultsChromatic Dispersion Analyzer 59Documenting ResultsDocumenting ResultsFor easier management, you may want to add comments and informat

Strany 67

Managing Results60 FTB-5800Documenting ResultsTo add specific information:1. On the Acquisitions tab, select the acquisition you wish to comment (the

Strany 68 - Printing Results

Managing ResultsChromatic Dispersion Analyzer 61Exporting Results and Graphs to ClipboardExporting Results and Graphs to ClipboardThe FTB-5800 Chromat

Strany 69

Managing Results62 FTB-5800Printing ResultsPrinting ResultsThe Chromatic Dispersion Analyzer allows you to print reports containing test information a

Strany 70

Managing ResultsChromatic Dispersion Analyzer 63Printing Results4. Select Print All Acquisitions or Print Current Acquisition Only, depending on the t

Strany 71 - ³ text files

Chromatic Dispersion Analyzer 11 Introducing the FTB-5800 Chromatic Dispersion AnalyzerIn today’s advanced optical network, chromatic dispersion manag

Strany 73 - Setting Export Parameters

Chromatic Dispersion Analyzer 656 Exporting CD Analyzer Files with the File Export ToolThe File Export tool has been designed to export chromatic disp

Strany 74 - 68 FTB-5800

Exporting CD Analyzer Files with the File Export Tool66 FTB-5800Starting and Exiting the File Export ToolThe File Export tool main window is displayed

Strany 75

Exporting CD Analyzer Files with the File Export ToolChromatic Dispersion Analyzer 67Setting Export ParametersSetting Export ParametersBefore exportin

Strany 76 - 70 FTB-5800

Exporting CD Analyzer Files with the File Export Tool68 FTB-5800Setting Export ParametersTo set export parameters:1. If necessary, open the File Expor

Strany 77 - 7 Maintenance

Exporting CD Analyzer Files with the File Export ToolChromatic Dispersion Analyzer 69Exporting Chromatic Dispersion FilesExporting Chromatic Dispersio

Strany 78

Exporting CD Analyzer Files with the File Export Tool70 FTB-5800Exporting Chromatic Dispersion Files4. Select the files.4a. Under Files To Be Exported

Strany 79

Chromatic Dispersion Analyzer 717 MaintenanceTo help ensure long, trouble-free operation:³ Always clean fiber-optic connectors before using them.³ Kee

Strany 80

Maintenance72 FTB-5800Cleaning EUI ConnectorsCleaning EUI ConnectorsRegular cleaning of EUI connectors will help maintain optimum performance. There i

Strany 81 - Recalibrating the Unit

MaintenanceChromatic Dispersion Analyzer 73Cleaning EUI ConnectorsNote: Make sure you don’t touch the soft end of the cleaning tip.6. Clean the ferrul

Strany 82 - Recycling and Disposal

Introducing the FTB-5800 Chromatic Dispersion Analyzer2 FTB-5800Main FeaturesThe architecture of the FTB-5800 Chromatic Dispersion Analyzer places the

Strany 83 - 8 Troubleshooting

Maintenance74 FTB-5800Cleaning Detector PortsCleaning Detector PortsRegular cleaning of detectors will help maintain measurement accuracy.To clean det

Strany 84

MaintenanceChromatic Dispersion Analyzer 75Recalibrating the UnitRecalibrating the UnitManufacturing and service center calibrations are based on the

Strany 85 - Viewing Online Documentation

Maintenance76 FTB-5800Recycling and Disposal (Applies to European Union Only)Recycling and Disposal (Applies to European Union Only)³ Unless otherwise

Strany 86 - FTB-5800-XX

Chromatic Dispersion Analyzer 778 TroubleshootingSolving Common ProblemsFatal Error Consequences Recommended SolutionModule temperature is too high fo

Strany 87 - Transportation

Troubleshooting78 FTB-5800Solving Common ProblemsWarning Consequences Recommended SolutionSource power is low. Some points will be grayed out on the g

Strany 88

TroubleshootingChromatic Dispersion Analyzer 79Viewing Online DocumentationViewing Online DocumentationAn online version of the FTB-5800 Chromatic Dis

Strany 89 - 9 Warranty

Troubleshooting80 FTB-5800Contacting the Technical Support GroupContacting the Technical Support GroupTo obtain after-sales service or technical suppo

Strany 90

TroubleshootingChromatic Dispersion Analyzer 81TransportationTransportationMaintain a temperature range within specifications when transporting the un

Strany 92 - 86 FTB-5800

Chromatic Dispersion Analyzer 839 WarrantyGeneral InformationEXFO Electro-Optical Engineering Inc. (EXFO) warrants this equipment against defects in m

Strany 93 - A Technical Specifications

Introducing the FTB-5800 Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 3Basic TheoryBasic TheoryChromatic dispersion is the natural broad

Strany 94

Warranty84 FTB-5800LiabilityLiabilityEXFO shall not be liable for damages resulting from the use of the product, nor shall be responsible for any fail

Strany 95 - Dispersion: Theory

WarrantyChromatic Dispersion Analyzer 85Service and RepairsService and RepairsEXFO commits to providing product service and repair for five years foll

Strany 96 - Expression for D

Warranty86 FTB-5800EXFO Service Centers WorldwideEXFO Service Centers WorldwideIf your product requires servicing, contact your nearest authorized ser

Strany 97

Chromatic Dispersion Analyzer 87A Technical SpecificationsIMPORTANTThe following technical specifications can change without notice. The information p

Strany 99

Chromatic Dispersion Analyzer 89B Measuring Chromatic Dispersion: TheoryEXFO’s Chromatic Dispersion Analyzer applies the phase-shift method, which con

Strany 100 - FTB-5800

Measuring Chromatic Dispersion: Theory90 FTB-5800Using Data Fits to Obtain DispersionUsing Data Fits to Obtain DispersionThis section gives you detail

Strany 101

Measuring Chromatic Dispersion: TheoryChromatic Dispersion Analyzer 91Using Data Fits to Obtain DispersionAs the previous table demonstrates, specific

Strany 102

Measuring Chromatic Dispersion: Theory92 FTB-5800Helping You Manage Chromatic DispersionHelping You Manage Chromatic DispersionThe zero-dispersion wav

Strany 103

IndexChromatic Dispersion Analyzer 93IndexAaccessing File Export ......... 65accuracy, results.........

Komentáře k této Příručce

Žádné komentáře