Exfo IQS-600 Integrated Qualification System Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Měřící nástroje Exfo IQS-600 Integrated Qualification System. EXFO IQS-600 Integrated Qualification System User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 357
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - User Guide

User GuideIntegrated Qualification SystemIQS-600

Strany 2

Introducing the IQS-600 Integrated Qualification System2 IQS-600Main FeaturesBoth controller and expansion units are designed to work with IQS modules

Strany 4

Integrated Qualification System 935 Using the IQS Manager InterfaceThis section helps you to work with the IQS Manager interface.Accessing Current Mod

Strany 5

Using the IQS Manager Interface94 IQS-600Accessing Current ModulesThe name, current status and serial number of each module installed on the unit you

Strany 6

Using the IQS Manager InterfaceIntegrated Qualification System 95Accessing Current ModulesIf you are currently in Remote mode and wish to revert to Lo

Strany 7

Using the IQS Manager Interface96 IQS-600Accessing Integrated ApplicationsAccessing Integrated ApplicationsThe Integrated Applications function tab is

Strany 8 - Certification Information

Using the IQS Manager InterfaceIntegrated Qualification System 97Working on Test Results (Offline Mode)Working on Test Results (Offline Mode)Your IQS-

Strany 9 - 1 Introducing the IQS-600

Using the IQS Manager Interface98 IQS-600Creating an Integrated Data DisplayCreating an Integrated Data DisplayNote: This feature is not available in

Strany 10 - Main Features

Using the IQS Manager InterfaceIntegrated Qualification System 99Creating an Integrated Data DisplayTo move monitor windows:1. On the monitor window y

Strany 11 - Available Models

Using the IQS Manager Interface100 IQS-600Viewing PDF FilesFor instructions on how to use the monitor window features of your IQS module, refer to the

Strany 12 - 4 IQS-600

Using the IQS Manager InterfaceIntegrated Qualification System 101Viewing PDF FilesTo view P D F f i l e s:1. From the Utilities function tab, selec

Strany 13 - IQS-610P-HS Controller Unit

Introducing the IQS-600 Integrated Qualification SystemIntegrated Qualification System 3Available ModelsAvailable ModelsBelow are diagrams to locate t

Strany 14 - 6 IQS-600

Using the IQS Manager Interface102 IQS-600Locating UnitsLocating UnitsNote: This feature is not available in Offline mode.Since you can connect many I

Strany 15 - IQS-610E-HS Expansion Unit

Using the IQS Manager InterfaceIntegrated Qualification System 103Accessing Utilities from IQS ManagerAccessing Utilities from IQS ManagerVarious util

Strany 17

Integrated Qualification System 1056 Accessing your IQS-600 RemotelyYou can access your unit remotely from a computer using either the Remote Desktop

Strany 18

Accessing your IQS-600 Remotely106 IQS-600Working with Remote DesktopWorking with Remote DesktopBy default, all the accounts with administrator rights

Strany 19 - Synchronization Ports

Accessing your IQS-600 RemotelyIntegrated Qualification System 107Working with Remote Desktop4. In the Connecting to Remote Desktop window, in the Com

Strany 20 - Dual Hard Disk Drive

Accessing your IQS-600 Remotely108 IQS-600Allowing User with Limited Accounts to Use Remote DesktopAllowing User with Limited Accounts to Use Remote D

Strany 21

Accessing your IQS-600 RemotelyIntegrated Qualification System 109Allowing User with Limited Accounts to Use Remote Desktop3. Under System, select All

Strany 22

Accessing your IQS-600 Remotely110 IQS-600Allowing User with Limited Accounts to Use Remote Desktop4. Under Remote Desktop, select Allow remote connec

Strany 23 - 2 Safety Information

Accessing your IQS-600 RemotelyIntegrated Qualification System 111Allowing User with Limited Accounts to Use Remote Desktop7. From the Select Users di

Strany 24 - Electrical Safety Information

Introducing the IQS-600 Integrated Qualification System4 IQS-600Available ModelsThe back of the IQS-605P-HS controller unit is where you find the peri

Strany 25

Accessing your IQS-600 Remotely112 IQS-600Allowing User with Limited Accounts to Use Remote Desktop10. From the list of users, select the user that yo

Strany 26

Accessing your IQS-600 RemotelyIntegrated Qualification System 113Allowing User with Limited Accounts to Use Remote DesktopRestarting or Turning Off Y

Strany 27 - Symbol Meaning

Accessing your IQS-600 Remotely114 IQS-600Working with TightVNCWorking with TightVNCThe control of your unit with TightVNC requires the TightVNC Serve

Strany 28

Accessing your IQS-600 RemotelyIntegrated Qualification System 115Working with TightVNCConfiguring the TightVNC ServerThe TightVNC Server is already i

Strany 29 - Integrated Qualification

Accessing your IQS-600 Remotely116 IQS-600Working with TightVNC4. To require a password from both the primary users and the view-only users, click Set

Strany 30

Accessing your IQS-600 RemotelyIntegrated Qualification System 117Working with TightVNCUsing the TightVNC ViewerThe TightVNC Viewer is used to control

Strany 31

Accessing your IQS-600 Remotely118 IQS-600Working with TightVNCUsing a Web Server as a ViewerYou can access to the TightVNC Server via a Web browser s

Strany 32 - 24 IQS-600

Accessing your IQS-600 RemotelyIntegrated Qualification System 119Working with TightVNC2. In the VNC Authentication dialog box, in the Password box, t

Strany 34

Integrated Qualification System 1217 Preparing for AutomationThe IQS-600 Integrated Qualification System was designed to meet the requirements of auto

Strany 35

Introducing the IQS-600 Integrated Qualification SystemIntegrated Qualification System 5Available ModelsIQS-610P-HS Controller UnitThe front of the IQ

Strany 36 - 28 IQS-600

Preparing for Automation122 IQS-600EXFO supplies commands that follow the guidelines determined by the SCPI consortium and LabVIEW drivers for all ava

Strany 37

Preparing for AutomationIntegrated Qualification System 123Control Technology CharacteristicsLocal ActiveX (COM)  Allows you to develop an applicatio

Strany 38 - 30 IQS-600

Preparing for Automation124 IQS-600For more information on programming aspects, see the section on using your product in an automated test environment

Strany 39 - Protective cover

Preparing for AutomationIntegrated Qualification System 125Configuring Your Integrated Qualification System for Working with GPIBConfiguring Your Inte

Strany 40 - 32 IQS-600

Preparing for Automation126 IQS-600Configuring Your Integrated Qualification System for Working with GPIBTo install the GPIB software and drivers for

Strany 41 - Retaining screw knob

Preparing for AutomationIntegrated Qualification System 127Configuring Your Integrated Qualification System for Working with GPIB4. In the installatio

Strany 42 - 34 IQS-600

Preparing for Automation128 IQS-600Configuring Your Integrated Qualification System for Working with GPIB6. Confirm which items will be installed on y

Strany 43

Preparing for AutomationIntegrated Qualification System 129Configuring Your Integrated Qualification System for Working with GPIB8. Read the license a

Strany 44 - 36 IQS-600

Preparing for Automation130 IQS-600Configuring Your Integrated Qualification System for Working with GPIB10. If you already have a user profile at Nat

Strany 45

Preparing for AutomationIntegrated Qualification System 131Configuring Your Integrated Qualification System for Working with GPIB12. Select which item

Strany 46 - On and Off

Introducing the IQS-600 Integrated Qualification System6 IQS-600Available ModelsThe back of the IQS-610P-HS controller unit is where you find the peri

Strany 47 -  a USB memory key

Preparing for Automation132 IQS-600Preparing Hardware for GPIB ControlPreparing Hardware for GPIB ControlIf you intend to use GPIB to remotely control

Strany 48 - 40 IQS-600

Preparing for AutomationIntegrated Qualification System 133Preparing Hardware for GPIB ControlThe IQS-600 Integrated Qualification System configuratio

Strany 49

Preparing for Automation134 IQS-600Linking Units with the GPIB PortLinking Units with the GPIB PortIf your IQS-600 Integrated Qualification System is

Strany 50

Preparing for AutomationIntegrated Qualification System 135Linking Units with the Serial PortLinking Units with the Serial PortYour IQS-600 Integrated

Strany 51 - Activating Software Options

Preparing for Automation136 IQS-600Getting Optimum Performance from Your Integrated Qualification SystemFor information on cabling, see Preparing Hard

Strany 52 - 44 IQS-600

Preparing for AutomationIntegrated Qualification System 137Getting Optimum Performance from Your Integrated Qualification System Output format (GPIB,

Strany 53

Preparing for Automation138 IQS-600Changing Communication SettingsChanging Communication SettingsCommunication settings cannot be modified without tur

Strany 54 - Software

Preparing for AutomationIntegrated Qualification System 139Changing Communication Settings3. Under Platform Startup, determine whether your module app

Strany 55 - Accessing IQS Manager

Preparing for Automation140 IQS-600Changing Communication Settings5. According to the communication type you have selected, customize the correspondin

Strany 56

Preparing for AutomationIntegrated Qualification System 141Changing Communication Settings For TCP/IPFor information on communicating with TCP/IP ove

Strany 57

Introducing the IQS-600 Integrated Qualification SystemIntegrated Qualification System 7Available ModelsIQS-610E-HS Expansion UnitThe front of the IQS

Strany 58 - 50 IQS-600

Preparing for Automation142 IQS-600Changing Communication SettingsTo revert to default RS-232 settings:1. Click the Default RS-232 Settings button.2.

Strany 59 - Qualification System

Preparing for AutomationIntegrated Qualification System 143Configuring DCOM Access to Your UnitConfiguring DCOM Access to Your UnitDCOM technology all

Strany 60 - 52 IQS-600

Preparing for Automation144 IQS-600Configuring DCOM Access to Your UnitSetting the General Security ParametersNote: To modify the security parameters,

Strany 61 - Back of the unit

Preparing for AutomationIntegrated Qualification System 145Configuring DCOM Access to Your Unit8. In the My Computer Properties dialog box, click the

Strany 62 - 54 IQS-600

Preparing for Automation146 IQS-600Configuring DCOM Access to Your Unit10. In the Access Permission dialog box, ensure that the Distributed COM Users

Strany 63

Preparing for AutomationIntegrated Qualification System 147Configuring DCOM Access to Your Unit13. Under Launch and Activation Permissions, click Edit

Strany 64 - Deactivating the LED Display

Preparing for Automation148 IQS-600Configuring DCOM Access to Your Unit14. In the Access Permission dialog box, ensure that the Distributed COM Users

Strany 65

Preparing for AutomationIntegrated Qualification System 149Configuring DCOM Access to Your UnitTo add a user explicitly:1. In the My Computer Properti

Strany 66 - 4. Click Options

Preparing for Automation150 IQS-600Configuring DCOM Access to Your Unit4. In the Select Users or Groups dialog box, under Enter the object names to se

Strany 67

Preparing for AutomationIntegrated Qualification System 151Configuring DCOM Access to Your Unit6. Confirm the newly added user has remote access permi

Strany 68 - 60 IQS-600

Introducing the IQS-600 Integrated Qualification System8 IQS-600Understanding the LEDsUnderstanding the LEDsThe LEDs on your Integrated Qualification

Strany 69

Preparing for Automation152 IQS-600Configuring DCOM Access to Your Unit9. In the Launch and Activation Permission dialog box, click Add.10. In the Sel

Strany 70 - 62 IQS-600

Preparing for AutomationIntegrated Qualification System 153Configuring DCOM Access to Your Unit12. Confirm the newly added user has Remote Launch and

Strany 71 - 4. Click Add a language

Preparing for Automation154 IQS-600Configuring DCOM Access to Your UnitCustomizing the Specific Security ParametersOnce you have defined the general s

Strany 72 - 64 IQS-600

Preparing for AutomationIntegrated Qualification System 155Configuring DCOM Access to Your Unit4. In the Authentication Level list, select Default.

Strany 73 - 9. Click Options

Preparing for Automation156 IQS-600Configuring DCOM Access to Your Unit5. In the EXFO KernosHost Properties dialog box, click the Security tab.6. Unde

Strany 74 - 66 IQS-600

Preparing for AutomationIntegrated Qualification System 157Configuring DCOM Access to Your Unit7. In the Launch and Activation Permission dialog box,

Strany 75 - Setting Date and Time Formats

Preparing for Automation158 IQS-600Configuring DCOM Access to Your Unit10. In the Launch and Activation Permission dialog box, select a user. 11. To a

Strany 76 - 68 IQS-600

Preparing for AutomationIntegrated Qualification System 159Configuring DCOM Access to Your Unit14. In the EXFO KernosHost Properties dialog box, click

Strany 77

Preparing for Automation160 IQS-600Configuring DCOM Access to Your Unit17. In the Select Users or Groups dialog box, under Enter the object names to s

Strany 78 - 70 IQS-600

Preparing for AutomationIntegrated Qualification System 161Configuring DCOM Access to Your Unit20. To allow this user to access the IQS-600 remotely,

Strany 79

Introducing the IQS-600 Integrated Qualification SystemIntegrated Qualification System 9Understanding the LEDsInterlock LEDWhen lit, it indicates that

Strany 80 - 72 IQS-600

Preparing for Automation162 IQS-600Configuring DCOM Access to Your UnitEnabling DCOM on Client ComputerNote: To run DCOMCNFG.EXE, you need Administrat

Strany 81 - Installing a Mouse

Preparing for AutomationIntegrated Qualification System 163Configuring DCOM Access to Your Unit4. Right-click My Computer, and then select Properties.

Strany 82 - 74 IQS-600

Preparing for Automation164 IQS-600Configuring DCOM Access to Your Unit10. Click the COM Security tab and, under Access Permissions, click Edit Limits

Strany 83 - Line Out port

Preparing for AutomationIntegrated Qualification System 165Configuring DCOM Access to Your UnitDisabling DCOM Access to Your IQS-600Note: To change th

Strany 84 - Installing a Microphone

Preparing for Automation166 IQS-600Configuring DCOM Access to Your Unit7. In the EXFO KernosHost Properties dialog box, click the Security tab.8. Unde

Strany 85 - Installing a Printer

Preparing for AutomationIntegrated Qualification System 167Preparing to Control Modules with a Dedicated ApplicationPreparing to Control Modules with

Strany 86 - 78 IQS-600

Preparing for Automation168 IQS-600Preparing to Control Modules with a Dedicated ApplicationTo activate or deactivate remote control:1. From the Utili

Strany 87 - Customizing Access Levels

Preparing for AutomationIntegrated Qualification System 169Preparing to Control Modules with a Dedicated Application3. From the Remote Control Configu

Strany 88 - 80 IQS-600

Preparing for Automation170 IQS-600Preparing to Control Modules with a Dedicated Application5. Under Description, type a relevant description (test in

Strany 89

Integrated Qualification System 1718 Using IQS Products in an Automated Test EnvironmentEXFO supplies commands that follow the guidelines determined b

Strany 90 - 82 IQS-600

Introducing the IQS-600 Integrated Qualification System10 IQS-600Understanding the Hardware Buttons and Selection Dial (IQS-605P-HS)Understanding the

Strany 91

Using IQS Products in an Automated Test Environment172 IQS-600Managing the States of Your IQS-600 Integrated Qualification SystemManaging the States o

Strany 92 - Adjusting the Fan Speed

Using IQS Products in an Automated Test EnvironmentIntegrated Qualification System 173Managing the States of Your IQS-600 Integrated Qualification Sys

Strany 93

Using IQS Products in an Automated Test Environment174 IQS-600Managing the States of Your IQS-600 Integrated Qualification SystemThe following diagram

Strany 94 -  active modules

Using IQS Products in an Automated Test EnvironmentIntegrated Qualification System 175Managing the States of Your IQS-600 Integrated Qualification Sys

Strany 95

Using IQS Products in an Automated Test Environment176 IQS-600Message ManagementMessage ManagementEach device that is physically connected to the GPIB

Strany 96 - 88 IQS-600

Using IQS Products in an Automated Test EnvironmentIntegrated Qualification System 177Message Management Except for the string and binary block conte

Strany 97

Using IQS Products in an Automated Test Environment178 IQS-600Message ManagementError/Event queue  Consists of a First-In, First-Out (FIFO) data stru

Strany 98 - 90 IQS-600

Using IQS Products in an Automated Test EnvironmentIntegrated Qualification System 179Standard Status Data StructureStandard Status Data StructureEach

Strany 99

Using IQS Products in an Automated Test Environment180 IQS-600Standard Status Data StructureThe following table presents a summary of the possible ope

Strany 100

Using IQS Products in an Automated Test EnvironmentIntegrated Qualification System 181Standard Status Data StructureThe following table presents a sum

Strany 101 - Interface

Introducing the IQS-600 Integrated Qualification SystemIntegrated Qualification System 11Locating Integrated Qualification System Synchronization Port

Strany 102 - Status Bar

Using IQS Products in an Automated Test Environment182 IQS-600Standard Status Data Structure

Strany 103 - Accessing Current Modules

Using IQS Products in an Automated Test EnvironmentIntegrated Qualification System 183SCPI Command StructureSCPI Command StructureThe information pres

Strany 104 - 96 IQS-600

Using IQS Products in an Automated Test Environment184 IQS-600SCPI Command StructureThe following table shows elements that are commonly used in the c

Strany 105

Using IQS Products in an Automated Test EnvironmentIntegrated Qualification System 185SCPI Command Structure<mnemonic> Element used in the const

Strany 106 - 98 IQS-600

Using IQS Products in an Automated Test Environment186 IQS-600SCPI Command StructureThere are also several conventions regarding command syntax: Spel

Strany 107

Using IQS Products in an Automated Test EnvironmentIntegrated Qualification System 187SCPI Command Structure You can build program messages allowing

Strany 108 - Viewing PDF Files

Using IQS Products in an Automated Test Environment188 IQS-600Consulting Data TypesConsulting Data TypesIf you need information about data types used

Strany 109

Using IQS Products in an Automated Test EnvironmentIntegrated Qualification System 189Writing Remote Control CodeWhen you write code, you must follow

Strany 110 - Locating Units

Using IQS Products in an Automated Test Environment190 IQS-600Error Message FormatError Message FormatSystem and device-specific errors are managed by

Strany 111

Using IQS Products in an Automated Test EnvironmentIntegrated Qualification System 191Working with EXFO COM ObjectsWorking with EXFO COM ObjectsThe IQ

Strany 112

ii IQS-600Copyright © 2008–2014 EXFO Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmit

Strany 113 - Remotely

Introducing the IQS-600 Integrated Qualification System12 IQS-600Dual Hard Disk DriveDual Hard Disk DriveThe optional RAID 1 dual hard disk drive perf

Strany 114 - Working with Remote Desktop

Using IQS Products in an Automated Test Environment192 IQS-600Working with EXFO LabVIEW DriversWorking with EXFO LabVIEW DriversEXFO provides you with

Strany 115

Using IQS Products in an Automated Test EnvironmentIntegrated Qualification System 193Working with EXFO LabVIEW DriversThe following table presents th

Strany 116 - Remote Desktop

Using IQS Products in an Automated Test Environment194 IQS-600Using the EXFO Getting Started ApplicationsUsing the EXFO Getting Started ApplicationsOn

Strany 117

Using IQS Products in an Automated Test EnvironmentIntegrated Qualification System 195Using the EXFO Getting Started ApplicationsOn the Front Panel, y

Strany 118 - 5. Click Select Users

Using IQS Products in an Automated Test Environment196 IQS-600Using the EXFO Getting Started ApplicationsThe following figure illustrates the State Ma

Strany 119

Using IQS Products in an Automated Test EnvironmentIntegrated Qualification System 197Using the EXFO Getting Started ApplicationsThe detail of this su

Strany 120 - 112 IQS-600

Using IQS Products in an Automated Test Environment198 IQS-600Using the EXFO Getting Started Applications6. When you are finished, select Close to end

Strany 121

Using IQS Products in an Automated Test EnvironmentIntegrated Qualification System 199Building and Using Custom VIsBuilding and Using Custom VIsEXFO L

Strany 122 - Working with TightVNC

Using IQS Products in an Automated Test Environment200 IQS-600Building and Using Custom VIsWhen you click an icon in the EXFO palette, the correspondi

Strany 123

Using IQS Products in an Automated Test EnvironmentIntegrated Qualification System 201Building and Using Custom VIsTo build a custom VI:1. Start LabVI

Strany 124 - IMPORTANT

Introducing the IQS-600 Integrated Qualification SystemIntegrated Qualification System 13ConventionsConventionsBefore using the product described in t

Strany 125 - Using the TightVNC Viewer

Using IQS Products in an Automated Test Environment202 IQS-600Building and Using Custom VIs3. Select EXFO IQS Base.4. From the EXFO IQS Base palette,

Strany 126

Using IQS Products in an Automated Test EnvironmentIntegrated Qualification System 203Building and Using Custom VIs8. Set the required parameters and

Strany 127

Using IQS Products in an Automated Test Environment204 IQS-600Building and Using Custom VIs10. When you are finished, add EXIQSBASE_CloseComm.vi to yo

Strany 128

Using IQS Products in an Automated Test EnvironmentIntegrated Qualification System 205Monitoring Remote CommandsMonitoring Remote CommandsIQS Manager

Strany 129 - 7 Preparing for Automation

Using IQS Products in an Automated Test Environment206 IQS-600Monitoring Remote Commands3. Do one of the following: If monitoring using GPIB, ActiveX

Strany 130 - LabWindows

Using IQS Products in an Automated Test EnvironmentIntegrated Qualification System 207Monitoring Remote Commands If monitoring using TCP/IP, which pr

Strany 131

Using IQS Products in an Automated Test Environment208 IQS-600Monitoring Remote CommandsWith the History parameter, you determine how many commands yo

Strany 132

Integrated Qualification System 2099 MaintenanceTo help ensure long, trouble-free operation: Always inspect fiber-optic connectors before using them

Strany 133

Maintenance210 IQS-600Replacing the FuseReplacing the FuseThe IQS-600 Integrated Qualification System contains a 10 A, L250 V, fast blow, low breaking

Strany 134 - 126 IQS-600

MaintenanceIntegrated Qualification System 211Managing Windows Updates3. Under Windows Update, click Turn automatic updating on or off.

Strany 136 - 128 IQS-600

Maintenance212 IQS-600Recycling and Disposal (Applies to European Union Only)4. Select the update options that best suit your needs.5. Click OK to con

Strany 137

Integrated Qualification System 21310 TroubleshootingSolving Common ProblemsProblem Probable Cause Recommended ActionIQS-600 module does not turn on.

Strany 138 - 130 IQS-600

Troubleshooting214 IQS-600Solving Common ProblemsThe controller unit does not detect the IQS modules in your expansion unit. The expansion unit is no

Strany 139 - Preparing for Automation

TroubleshootingIntegrated Qualification System 215Solving Common ProblemsYou receive an error message indicating that you must insert your high-speed

Strany 140

Troubleshooting216 IQS-600Restoring Your Controller Unit to Normal OperationRestoring Your Controller Unit to Normal OperationIf you ever encounter ma

Strany 141 - Mnemonic Function

TroubleshootingIntegrated Qualification System 217Restoring Your Controller Unit to Normal OperationWhen you want to restore your unit, there are seve

Strany 142 - 134 IQS-600

Troubleshooting218 IQS-600Restoring Your Controller Unit to Normal OperationCAUTION Before starting one of the recovery operations, connect your unit

Strany 143

TroubleshootingIntegrated Qualification System 219Restoring Your Controller Unit to Normal OperationTo revert your unit to a previous state:1. Ensure

Strany 144

Troubleshooting220 IQS-600Restoring Your Controller Unit to Normal Operation4. Click Settings > Change PC settings.5. Click Update and recovery.

Strany 145 -  PACKed

TroubleshootingIntegrated Qualification System 221Restoring Your Controller Unit to Normal Operation6. Click Recovery.7. If you want to refresh or res

Strany 146 - 138 IQS-600

Integrated Qualification System 152 Safety Information Laser Safety InformationYour IQS-600 Integrated Qualification System does not include laser com

Strany 147

Troubleshooting222 IQS-600Restoring Your Controller Unit to Normal Operation8. If you want to restore your unit (with a WIM file), proceed as follows:

Strany 148 -  For RS-232

TroubleshootingIntegrated Qualification System 223Restoring Your Controller Unit to Normal Operation8c. Click Platform Imaging Utility to display the

Strany 149 -  For TCP/IP

Troubleshooting224 IQS-600Restoring Your Controller Unit to Normal Operation8e. From the Platform Servicing and Imaging Utility wizard, select Restore

Strany 150

TroubleshootingIntegrated Qualification System 225Restoring Your Controller Unit to Normal Operation8g. Locate the USB key, and then double-click its

Strany 151 -  register callback events

Troubleshooting226 IQS-600Restoring Your Controller Unit to Normal OperationTo create a WIM file for your unit:1. On your platform, put the mouse curs

Strany 152 - 144 IQS-600

TroubleshootingIntegrated Qualification System 227Restoring Your Controller Unit to Normal Operation2. Click Settings > Change PC settings.3. Click

Strany 153

Troubleshooting228 IQS-600Restoring Your Controller Unit to Normal Operation4. Click Recovery.

Strany 154 - 146 IQS-600

TroubleshootingIntegrated Qualification System 229Restoring Your Controller Unit to Normal Operation5. Under Advanced Startup, click Restart now.6. Un

Strany 155

Troubleshooting230 IQS-600Restoring Your Controller Unit to Normal Operation7. Click Platform Imaging Utility to display the corresponding application

Strany 156 - 148 IQS-600

TroubleshootingIntegrated Qualification System 231Restoring Your Controller Unit to Normal Operation9. From the Platform Servicing and Imaging Utility

Strany 157

Safety Information16 IQS-600Electrical Safety InformationElectrical Safety InformationThis unit uses an international safety standard three-wire power

Strany 158 - 5. Click OK

Troubleshooting232 IQS-600Restoring Your Controller Unit to Normal Operation10. Click Browse.11. Locate the USB key, and then double-click its identif

Strany 159

TroubleshootingIntegrated Qualification System 233Restoring Your Controller Unit to Normal Operation14. Click Start. Note: The time required to create

Strany 160 - 152 IQS-600

Troubleshooting234 IQS-600Viewing Online DocumentationViewing Online DocumentationAn online version of the IQS-600 Integrated Qualification System use

Strany 161

TroubleshootingIntegrated Qualification System 235Contacting the Technical Support GroupContacting the Technical Support GroupTo obtain after-sales se

Strany 162 - 154 IQS-600

Troubleshooting236 IQS-600Viewing System InformationViewing System InformationThe System Information function tab contains important information about

Strany 163

TroubleshootingIntegrated Qualification System 237Viewing System InformationConsulting the Kits Installed TabThe Kits Installed tab allows you to view

Strany 164

Troubleshooting238 IQS-600Viewing System Information2. Select Kits Installed to view which kits are installed on your unit.The first column represents

Strany 165

TroubleshootingIntegrated Qualification System 239Viewing System InformationConsulting the Components TabThe Components tab provides a list of all the

Strany 166 - 158 IQS-600

Troubleshooting240 IQS-600TransportationNote: You cannot change the filename for this list. If you save the list a second time, the first list will be

Strany 167

Integrated Qualification System 24111 WarrantyGeneral InformationEXFO Inc. (EXFO) warrants this equipment against defects in material and workmanship

Strany 168 - 160 IQS-600

Safety InformationIntegrated Qualification System 17Electrical Safety InformationThe color coding used in the electric cable depends on the cable. New

Strany 169

Warranty242 IQS-600ExclusionsExclusionsEXFO reserves the right to make changes in the design or construction of any of its products at any time withou

Strany 170 - 162 IQS-600

WarrantyIntegrated Qualification System 243Service and RepairsService and RepairsEXFO commits to providing product service and repair for five years f

Strany 171

Warranty244 IQS-600EXFO Service Centers WorldwideEXFO Service Centers WorldwideIf your product requires servicing, contact your nearest authorized ser

Strany 172 - 164 IQS-600

Integrated Qualification System 245A Technical SpecificationsNote: The IQS-600 Integrated Qualification System is intended for indoor use only.IMPORTA

Strany 173

Technical Specifications246 IQS-600Software and driversOperating system bWindows 8.1 ProEXFO software IQS ManagerLocal control ActiveX/COM library usi

Strany 174 - 166 IQS-600

Integrated Qualification System 247B SCPI-Based ErrorsError NumberDescription Probable Cause–100 “Command error” This is the generic syntax error for

Strany 175

SCPI-Based Errors248 IQS-600–110 “Command header error”An error was detected in the header. This error message should be used when the device cannot d

Strany 176

SCPI-Based ErrorsIntegrated Qualification System 249–123 “Exponent too large” The magnitude of the exponent was larger than 32000 (see IEEE 488.2, 7.7

Strany 177

SCPI-Based Errors250 IQS-600–150 “String data error” This error, as well as errors –151 through –159, are generated when parsing a string data element

Strany 178 - 170 IQS-600

SCPI-Based ErrorsIntegrated Qualification System 251–180 “Macro error” This error, as well as errors –181 through –189, are generated when defining a

Strany 179 - Automated Test Environment

Safety Information18 IQS-600Electrical Safety InformationEquipment RatingsTemperature Operation Storage 0 °C to 40 °C (32 °F to 104 °F) –40 °C to

Strany 180

SCPI-Based Errors252 IQS-600–210 “Trigger error” -----–211 “Trigger ignored” Indicates that a GET, *TRG, or triggering signal was received and recogni

Strany 181

SCPI-Based ErrorsIntegrated Qualification System 253–222 “Data out of range” Indicates that a legal program data element was parsed but could not be e

Strany 182

SCPI-Based Errors254 IQS-600–233 “Invalid version” Indicates that a legal program data element was parsed but could not be executed because the versio

Strany 183

SCPI-Based ErrorsIntegrated Qualification System 255–253 “Corrupt media” Indicates that a legal program command or query could not be executed because

Strany 184 - Message Management

SCPI-Based Errors256 IQS-600–260 “Expression error” Indicates that an expression program data element related error occurred. This error message shoul

Strany 185

SCPI-Based ErrorsIntegrated Qualification System 257–275 “Macro definition too long”Indicates that a syntactically legal macro program data sequence c

Strany 186

SCPI-Based Errors258 IQS-600–284 “Program currently running”Certain operations dealing with programs may be illegal while the program is running; for

Strany 187 - ESR and ESE

SCPI-Based ErrorsIntegrated Qualification System 259–312 “PUD memory lost” Indicates that the protected user data saved by the *PUD command has been l

Strany 188 - STB and SRE

SCPI-Based Errors260 IQS-600–363 “Input buffer overrun” Software or hardware input buffer on serial port overflows with data caused by improper or non

Strany 189

SCPI-Based ErrorsIntegrated Qualification System 261–700 “Request control” The instrument requested to become the active IEEE 488.1 controller-in-char

Strany 190 - 182 IQS-600

Safety InformationIntegrated Qualification System 19Other Safety Symbols on Your UnitOther Safety Symbols on Your UnitOne or more of the following sym

Strany 192 - Item Meaning

Integrated Qualification System 263CData TypesThe following section provides an overview of the most common data types that may appear in EXFO’s docum

Strany 193

Data Types264 IQS-600Applicable Data Types for Input—IEEE 488.2Applicable Data Types for Input—IEEE 488.2 <PROGRAM MESSAGE TERMINATOR>In the di

Strany 194 - Short form (small words

Data TypesIntegrated Qualification System 265Applicable Data Types for Input—IEEE 488.2 <CHARACTER PROGRAM DATA>This data type is used to send

Strany 195

Data Types266 IQS-600Applicable Data Types for Input—IEEE 488.2 <NON-DECIMAL NUMERIC PROGRAM DATA>This data type is used for integer representa

Strany 196 - Writing Remote Control Code

Data TypesIntegrated Qualification System 267Applicable Data Types for Input—IEEE 488.2Examples: #Q1234567, #q1275, #q07Examples: #B10010111, #b10110,

Strany 197

Data Types268 IQS-600Applicable Data Types for Input—IEEE 488.2 <STRING PROGRAM DATA>This data type is used for strings containing 7-bit ASCII

Strany 198 - Error Message Format

Data TypesIntegrated Qualification System 269Applicable Data Types for Input—IEEE 488.2 <ARBITRARY BLOCK PROGRAM DATA>This data type is used to

Strany 199 - Working with EXFO COM Objects

Data Types270 IQS-600Applicable Data Types for Input—IEEE 488.2 <SUFFIX PROGRAM DATA>This data type is used when units and multipliers have to

Strany 200

Data TypesIntegrated Qualification System 271Applicable Data Types for Input—IEEE 488.2The table below illustrates the possible forms for <suffix m

Strany 202 - 194 IQS-600

Data Types272 IQS-600Applicable Data Types for Input—IEEE 488.2The table below gives the possible forms for <suffix unit>: Reference Unit Suffix

Strany 203

Data TypesIntegrated Qualification System 273Applicable Data Types for Output —IEEE 488.2Applicable Data Types for Output —IEEE 488.2 <RESPONSE ME

Strany 204 - 196 IQS-600

Data Types274 IQS-600Applicable Data Types for Output —IEEE 488.2 <NR1 NUMERIC RESPONSE DATA> (or <NR1>)This data type is used by a devic

Strany 205 - Instrument driver VI

Data TypesIntegrated Qualification System 275Applicable Data Types for Output —IEEE 488.2 <NR3 NUMERIC RESPONSE DATA> (or <NR3>)This data

Strany 206

Data Types276 IQS-600Applicable Data Types for Output —IEEE 488.2 Special Numeric Values Received on OutputIn some cases, an instrument may send valu

Strany 207 - Building and Using Custom VIs

Data TypesIntegrated Qualification System 277Applicable Data Types for Output —IEEE 488.2 <HEXADECIMAL NUMERIC RESPONSE DATA>This data type is

Strany 208 - 200 IQS-600

Data Types278 IQS-600Applicable Data Types for Output —IEEE 488.2 <OCTAL NUMERIC RESPONSE DATA>This data type is used by a device to return int

Strany 209

Data TypesIntegrated Qualification System 279Applicable Data Types for Output —IEEE 488.2 <BINARY NUMERIC RESPONSE DATA>This data type is used

Strany 210 - 202 IQS-600

Data Types280 IQS-600Applicable Data Types for Output —IEEE 488.2 <DEFINITE LENGTH ARBITRARY BLOCK RESPONSE DATA>This data type is used by a de

Strany 211

Data TypesIntegrated Qualification System 281Applicable Data Types for Output —IEEE 488.2 <INDEFINITE LENGTH ARBITRARY BLOCK RESPONSE DATA>This

Strany 212 - 204 IQS-600

Integrated Qualification System 213 Getting Started with Your Integrated Qualification SystemYou can either use your IQS-600 Integrated Qualification

Strany 213 - Monitoring Remote Commands

Data Types282 IQS-600Applicable Data Types for Output —IEEE 488.2 <SUFFIX RESPONSE DATA>This data type is used by a device to return units and

Strany 214 - 206 IQS-600

Data TypesIntegrated Qualification System 283Applicable Data Types for Input—SCPIApplicable Data Types for Input—SCPISCPI data types include the IEEE

Strany 215

Data Types284 IQS-600Special Numeric Values Received on OutputSpecial Numeric Values Received on OutputIt is possible that an instrument returns unusu

Strany 216 - 208 IQS-600

Integrated Qualification System 285D IEEE 488.2 and Specific CommandsThis chapter presents detailed information about the commands and queries supplie

Strany 217 - 9 Maintenance

IEEE 488.2 and Specific Commands286 IQS-600IEEE 488.2 Required CommandsIEEE 488.2 Required Commands*SRE Service request enable command(See *SRE on pag

Strany 218 - Managing Windows Updates

IEEE 488.2 and Specific CommandsIntegrated Qualification System 287IEEE 488.2 Required Commands*ESEDescription The *ESE command sets the Standard Even

Strany 219 - Maintenance

IEEE 488.2 and Specific Commands288 IQS-600IEEE 488.2 Required Commands The table below shows the contents of this register.A value of 1 in the Enable

Strany 220 - Recycling and Disposal

IEEE 488.2 and Specific CommandsIntegrated Qualification System 289IEEE 488.2 Required Commands*ESE?Description The *ESE? query allows the programmer

Strany 221 - 10 Troubleshooting

IEEE 488.2 and Specific Commands290 IQS-600IEEE 488.2 Required CommandsResponse(s) RegisterValue: The response data syntax for <RegisterValue> i

Strany 222

IEEE 488.2 and Specific CommandsIntegrated Qualification System 291IEEE 488.2 Required Commands*ESR?Description The *ESR? query allows the programmer

Strany 223

Integrated Qualification System iiiContentsCertification Information ...

Strany 224

Getting Started with Your Integrated Qualification System22 IQS-600Installing Your Controller and Expansion Units in a RackmountInstalling Your Contro

Strany 225

IEEE 488.2 and Specific Commands292 IQS-600IEEE 488.2 Required CommandsResponse(s) RegisterValue: The response data syntax for <RegisterValue> i

Strany 226

IEEE 488.2 and Specific CommandsIntegrated Qualification System 293IEEE 488.2 Required Commands*IDN?Description The intent of the *IDN? query is for t

Strany 227

IEEE 488.2 and Specific Commands294 IQS-600IEEE 488.2 Required CommandsField 3 (Serial number): ASCII character (0 if not available)Field 4 (Firmwar

Strany 228 - 5. Click Update and recovery

IEEE 488.2 and Specific CommandsIntegrated Qualification System 295IEEE 488.2 Required Commands*OPCDescription The *OPC command allows synchronization

Strany 229 - 6. Click Recovery

IEEE 488.2 and Specific Commands296 IQS-600IEEE 488.2 Required Commands*OPC?Description The *OPC? query allows synchronization between the instrument

Strany 230

IEEE 488.2 and Specific CommandsIntegrated Qualification System 297IEEE 488.2 Required Commands*RSTDescription The *RST command performs a device rese

Strany 231

IEEE 488.2 and Specific Commands298 IQS-600IEEE 488.2 Required Commands*SREDescription The *SRE command sets the Service Request Enable Register bits.

Strany 232 - 8f. Click Browse

IEEE 488.2 and Specific CommandsIntegrated Qualification System 299IEEE 488.2 Required CommandsSee the contents of this register below.A bit value of

Strany 233

IEEE 488.2 and Specific Commands300 IQS-600IEEE 488.2 Required Commands*SRE?Description The *SRE? query allows the programmer to determine the current

Strany 234

IEEE 488.2 and Specific CommandsIntegrated Qualification System 301IEEE 488.2 Required CommandsResponse(s) RegisterValue: The response data syntax for

Strany 235 - 3. Click Update and recovery

Getting Started with Your Integrated Qualification SystemIntegrated Qualification System 23Installing Your Controller and Expansion Units in a Rackmou

Strany 236 - 4. Click Recovery

IEEE 488.2 and Specific Commands302 IQS-600IEEE 488.2 Required Commands*STB?Description The *STB? query allows the programmer to read the status byte

Strany 237

IEEE 488.2 and Specific CommandsIntegrated Qualification System 303IEEE 488.2 Required CommandsResponse(s) RegisterValue: The response data syntax for

Strany 238

IEEE 488.2 and Specific Commands304 IQS-600IEEE 488.2 Required Commands*TST?Description The *TST? query causes an internal self-test and places a resp

Strany 239 - WIM file, an then click Next

IEEE 488.2 and Specific CommandsIntegrated Qualification System 305IEEE 488.2 Required Commands*WAIDescription The *WAI command shall prevent the devi

Strany 240 - 232 IQS-600

IEEE 488.2 and Specific Commands306 IQS-600Specific Commands—Quick ReferenceSpecific Commands—Quick ReferenceThe table below contains a summary of the

Strany 241

IEEE 488.2 and Specific CommandsIntegrated Qualification System 307Specific CommandsSpecific Commands:FORMat[:DATA]Description The FORMat[:DATA] comma

Strany 242 - Viewing Online Documentation

IEEE 488.2 and Specific Commands308 IQS-600Specific CommandsIn ASCii format, the numeric data is transferred to ASCii bytes in <NR1 NUMERIC RESPONS

Strany 243

IEEE 488.2 and Specific CommandsIntegrated Qualification System 309Specific Commands:FORMat[:DATA]?Description The FORMat[:DATA]? query returns the da

Strany 244 - Viewing System Information

IEEE 488.2 and Specific Commands310 IQS-600Specific CommandsWhen the data is returned in ASCII, the <Length> is the number of significant digits

Strany 245

IEEE 488.2 and Specific CommandsIntegrated Qualification System 311Specific Commands:INSTrument:CATalog?Description The INSTrument:CATalog? query retu

Strany 246 - 238 IQS-600

Getting Started with Your Integrated Qualification System24 IQS-600Installing Your Controller and Expansion Units in a Rackmount3. Assemble the rackmo

Strany 247 - Consulting the Components Tab

IEEE 488.2 and Specific Commands312 IQS-600Specific Commands:INSTrument:CATalog:FULL?Description The INSTrument:CATalog:FULL? returns a list of <ST

Strany 248 - Transportation

IEEE 488.2 and Specific CommandsIntegrated Qualification System 313Specific Commands:SYSTem:DATEDescription The SYSTem:DATE command is used to set the

Strany 249 - 11 Warranty

IEEE 488.2 and Specific Commands314 IQS-600Specific Commands Day: The program data syntax for <Day> is defined as a <DECIMAL NUMERIC PROGRAM

Strany 250 - Certification

IEEE 488.2 and Specific CommandsIntegrated Qualification System 315Specific Commands:SYSTem:DATE?Description The SYSTem:DATE query returns the instrum

Strany 251 - Service and Repairs

IEEE 488.2 and Specific Commands316 IQS-600Specific CommandsResponse(s)  Year: The response data syntax for <Year> is defined as a <NR1 NUME

Strany 252 - 244 IQS-600

IEEE 488.2 and Specific CommandsIntegrated Qualification System 317Specific Commands:SYSTem:ERRor[:NEXT]?Description The SYSTem:ERRor[:NEXT]? queries

Strany 253 - A Technical Specifications

IEEE 488.2 and Specific Commands318 IQS-600Specific CommandsThe <Description[,Info]> parameter of the full response is a quoted string containin

Strany 254 - Technical Specifications

IEEE 488.2 and Specific CommandsIntegrated Qualification System 319Specific Commands:SYSTem:TIMEDescription This device has an internal clock and impl

Strany 255 - B SCPI-Based Errors

IEEE 488.2 and Specific Commands320 IQS-600Specific Commands Seconds: The program data syntax for <Seconds> is defined as a <DECIMAL NUMERIC

Strany 256 - Description Probable Cause

IEEE 488.2 and Specific CommandsIntegrated Qualification System 321Specific Commands:SYSTem:TIME?Description This device has an internal clock and imp

Strany 257

Getting Started with Your Integrated Qualification SystemIntegrated Qualification System 25Installing Your Controller and Expansion Units in a Rackmou

Strany 258 - 250 IQS-600

IEEE 488.2 and Specific Commands322 IQS-600Specific CommandsResponse(s)  Hour: The response data syntax for <Hour> is defined as a <NR1 NUME

Strany 259

IEEE 488.2 and Specific CommandsIntegrated Qualification System 323Specific Commands:SYSTem:VERSion?Description The SYSTem:VERSion? query returns a va

Strany 261

Integrated Qualification System 325E COM Properties and EventsThe IQS-600 Integrated Qualification System also provides objects based on Microsoft Com

Strany 262 - 254 IQS-600

COM Properties and Events326 IQS-600ActiveX (COM/DCOM)—Quick ReferenceActiveX (COM/DCOM)—Quick ReferenceThe following diagram illustrates the differen

Strany 263

COM Properties and EventsIntegrated Qualification System 327PropertiesPropertiesWriteDescription This method allows you to send a program message (sin

Strany 264 - 256 IQS-600

COM Properties and Events328 IQS-600PropertiesWriteBinaryDescription This method allows you to send a program message (single command or compound of c

Strany 265

COM Properties and EventsIntegrated Qualification System 329PropertiesReadDescription This method allows you to retrieve all the data from the device

Strany 266 - 258 IQS-600

COM Properties and Events330 IQS-600PropertiesReadBinaryDescription This method allows you to retrieve data from the device output queue in a binary f

Strany 267

COM Properties and EventsIntegrated Qualification System 331PropertiesFor example, if you receive this response (here, values are expressed in decimal

Strany 268 - 260 IQS-600

Getting Started with Your Integrated Qualification System26 IQS-600Connecting One or More Expansion Units to a Controller UnitConnecting One or More E

Strany 269

COM Properties and Events332 IQS-600PropertiesDeviceClearDescription This method performs a Device Clear operation as specified in the IEEE 488.1 stan

Strany 270

COM Properties and EventsIntegrated Qualification System 333PropertiesLockoutStateDescription This property returns or sets the device’s lockout state

Strany 271 - CData Types

COM Properties and Events334 IQS-600EventsEventsRequestServiceDescription This event is triggered whenever the device causes a Service Request (SRQ).P

Strany 272 - 264 IQS-600

Integrated Qualification System 335F Using the IQS-9600 Utility ModuleThe IQS-9600 Utility Module provides a secure, standardized way of integrating c

Strany 273

Using the IQS-9600 Utility Module336 IQS-600

Strany 274 - 266 IQS-600

Using the IQS-9600 Utility ModuleIntegrated Qualification System 337

Strany 276 -  <STRING PROGRAM DATA>

IndexIntegrated Qualification System 339IndexAAbout tab... 236AC requirements ...

Strany 277

Index340 IQS-600communicationActiveX ... 123changing settings ... 138default

Strany 278 -  <SUFFIX PROGRAM DATA>

IndexIntegrated Qualification System 341examplesCOM/DCOM... 191LabVIEW ...

Strany 279 - Name Value Mnemonic

Getting Started with Your Integrated Qualification SystemIntegrated Qualification System 27Connecting One or More Expansion Units to a Controller Unit

Strany 280 - Reference Unit Suffix Unit

Index342 IQS-600IQ module, removing ... 35IQS-600controller... 121turning off

Strany 281

IndexIntegrated Qualification System 343moving, monitor windows ... 98multiple capabilities ...

Strany 282 - 274 IQS-600

Index344 IQS-600Qqueueerror/event... 178input... 176output ..

Strany 283

IndexIntegrated Qualification System 345sending datawith Ethernet port ... 134with GPIB port ...

Strany 284 - 276 IQS-600

Index346 IQS-600repairing... 17status... 172ventilation .

Strany 285

NOTICE抩⛙CHINESE REGULATION ON RESTRICTION OF HAZARDOUS SUBSTANCES₼⦌␂ℝ☀⹂䓸德棟Ⓟ䤓屓⸩NAMES AND CONTENTS OF THE TOXIC OR HAZARDOUS SUBSTANCES OR ELEMENTS CONT

Strany 286

MARKING REQUIREMENTS㪖㽷尐㻑Productℶ❐Environmental protection use period (years)䘾⬒≬㔳∎䞷㦮棟 ( ㄃ )Logo㪖㉦This E;)2 product㦻 EXFO ℶ❐10Batterya䟄㻯aa. If applicabl

Strany 287

www.EXFO.com · [email protected]/N: 1066802CORPORATE HEADQUARTERS 400 Godin Avenue Quebec (Quebec) G1M 2K2 CANADATel.: 1 418 683-0211 · Fax: 1 418 683-

Strany 288 - 280 IQS-600

Getting Started with Your Integrated Qualification System28 IQS-600Connecting One or More Expansion Units to a Controller Unit2. Connect the other end

Strany 289

Getting Started with Your Integrated Qualification SystemIntegrated Qualification System 29Connecting One or More Expansion Units to a Controller Unit

Strany 290 - 282 IQS-600

Getting Started with Your Integrated Qualification System30 IQS-600Inserting and Removing Test ModulesInserting and Removing Test ModulesCAUTIONNever

Strany 291

Getting Started with Your Integrated Qualification SystemIntegrated Qualification System 31Inserting and Removing Test ModulesTo insert a module into

Strany 292 - 488.2 on page 273

iv IQS-6004 Setting Up Your Integrated Qualification System ...51Calibrating Your Touchscreen (IQS-605P-HS) ...

Strany 293 - Commands

Getting Started with Your Integrated Qualification System32 IQS-600Inserting and Removing Test Modules4. Insert the protruding edges of the module int

Strany 294 - IEEE 488.2 Required Commands

Getting Started with Your Integrated Qualification SystemIntegrated Qualification System 33Inserting and Removing Test ModulesThe module is correctly

Strany 295

Getting Started with Your Integrated Qualification System34 IQS-600Inserting and Removing Test Modules3. Cover empty slots with the supplied protectiv

Strany 296 - Bit Weight Meaning

Getting Started with Your Integrated Qualification SystemIntegrated Qualification System 35Inserting and Removing Test ModulesSince IQ modules do not

Strany 297

Getting Started with Your Integrated Qualification System36 IQS-600Safeguarding Units with the InterlockSafeguarding Units with the InterlockEXFO’s mo

Strany 298 - 290 IQS-600

Getting Started with Your Integrated Qualification SystemIntegrated Qualification System 37Safeguarding Units with the InterlockIf you use modules fea

Strany 299

Getting Started with Your Integrated Qualification System38 IQS-600Turning the Integrated Qualification System On and OffTurning the Integrated Qualif

Strany 300 - 292 IQS-600

Getting Started with Your Integrated Qualification SystemIntegrated Qualification System 39Installing or Upgrading the ApplicationsInstalling or Upgra

Strany 301

Getting Started with Your Integrated Qualification System40 IQS-600Installing or Upgrading the ApplicationsTo update or reinstall Update Manager:1. If

Strany 302 - 294 IQS-600

Getting Started with Your Integrated Qualification SystemIntegrated Qualification System 41Installing or Upgrading the ApplicationsTo install or upgra

Strany 303

Integrated Qualification System v7 Preparing for Automation ... 121Configuring Yo

Strany 304 - 296 IQS-600

Getting Started with Your Integrated Qualification System42 IQS-600Activating Software OptionsActivating Software OptionsThe software options purchase

Strany 305

Getting Started with Your Integrated Qualification SystemIntegrated Qualification System 43Activating Software OptionsTo activate the options for your

Strany 306 - 298 IQS-600

Getting Started with Your Integrated Qualification System44 IQS-600Activating Software Options6. In the Platform Options tab, use the Browse button to

Strany 307

Getting Started with Your Integrated Qualification SystemIntegrated Qualification System 45Activating Software OptionsTo activate software options for

Strany 308 - 300 IQS-600

Getting Started with Your Integrated Qualification System46 IQS-600Protecting your Unit with an Antivirus Software6. In the Module Options tab, use th

Strany 309

Getting Started with Your Integrated Qualification SystemIntegrated Qualification System 47Accessing IQS ManagerAccessing IQS ManagerWhen your IQS-600

Strany 310 - 302 IQS-600

Getting Started with Your Integrated Qualification System48 IQS-600Exiting IQS ManagerExiting IQS ManagerTo exit IQS Manager:1. Click the Exit button,

Strany 311

Getting Started with Your Integrated Qualification SystemIntegrated Qualification System 49Installing EXFO LabVIEW DriversInstalling EXFO LabVIEW Driv

Strany 312 - 304 IQS-600

Getting Started with Your Integrated Qualification System50 IQS-600Installing EXFO LabVIEW Drivers3. Once the software installation is complete, insta

Strany 313

Integrated Qualification System 514 Setting Up Your Integrated Qualification SystemCalibrating Your Touchscreen (IQS-605P-HS)The touchscreen simplifie

Strany 314 - 306 IQS-600

vi IQS-60011 Warranty ...241General Information ...

Strany 315 - Specific Commands

Setting Up Your Integrated Qualification System52 IQS-600Installing an External MonitorTo calibrate your touchscreen:1. Start Windows. 2. On the taskb

Strany 316 - :FORMat[:DATA]

Setting Up Your Integrated Qualification SystemIntegrated Qualification System 53Installing an External MonitorCAUTIONDo not put the monitor directly

Strany 317 - :FORMat[:DATA]?

Setting Up Your Integrated Qualification System54 IQS-600Adjusting the Display and SoundAdjusting the Display and SoundDifferent working environments

Strany 318

Setting Up Your Integrated Qualification SystemIntegrated Qualification System 55Adjusting the Display and SoundNote: You can also access the sound le

Strany 319 - :INSTrument:CATalog?

Setting Up Your Integrated Qualification System56 IQS-600Changing the Backlight Level (IQS-605P-HS)Changing the Backlight Level (IQS-605P-HS)The backl

Strany 320 - :INSTrument:CATalog:FULL?

Setting Up Your Integrated Qualification SystemIntegrated Qualification System 57Selecting the Language of OperationSelecting the Language of Operatio

Strany 321 - :SYSTem:DATE

Setting Up Your Integrated Qualification System58 IQS-600Selecting the Language of Operation3. Select the desired language from the list.Note: If the

Strany 322

Setting Up Your Integrated Qualification SystemIntegrated Qualification System 59Selecting the Language of Operation5. If you want to select another k

Strany 323 - :SYSTem:DATE?

Setting Up Your Integrated Qualification System60 IQS-600Selecting the Language of Operation5b. Select the desired keyboard layout, then click Add.

Strany 324

Setting Up Your Integrated Qualification SystemIntegrated Qualification System 61Selecting the Language of Operation6. Under Windows display language,

Strany 325 - :SYSTem:ERRor[:NEXT]?

Certification InformationIntegrated Qualification System viiCertification InformationNorth America Regulatory StatementThis unit was certified by an a

Strany 326

Setting Up Your Integrated Qualification System62 IQS-600Selecting the Language of OperationTo download language packs:1. Ensure that your unit has ac

Strany 327 - :SYSTem:TIME

Setting Up Your Integrated Qualification SystemIntegrated Qualification System 63Selecting the Language of Operation4. Click Add a language.5. Browse

Strany 328

Setting Up Your Integrated Qualification System64 IQS-600Selecting the Language of Operation7. Select the desired sub-language, and then click Add.

Strany 329 - :SYSTem:TIME?

Setting Up Your Integrated Qualification SystemIntegrated Qualification System 65Selecting the Language of Operation8. Select the desired language fro

Strany 330

Setting Up Your Integrated Qualification System66 IQS-600Selecting the Language of Operation10. Click Download and install language pack.11. When the

Strany 331 - :SYSTem:VERSion?

Setting Up Your Integrated Qualification SystemIntegrated Qualification System 67Setting Date and Time FormatsSetting Date and Time FormatsBy default,

Strany 332

Setting Up Your Integrated Qualification System68 IQS-600Setting Date and Time Formats3. Refine the settings according to your needs.4. Click Apply to

Strany 333 - E COM Properties and Events

Setting Up Your Integrated Qualification SystemIntegrated Qualification System 69Adjusting the Date, Time and Time ZoneAdjusting the Date, Time and Ti

Strany 334 - COM Properties and Events

Setting Up Your Integrated Qualification System70 IQS-600Installing an External KeyboardInstalling an External KeyboardYour IQS-600 Integrated Qualifi

Strany 335 - Properties

Setting Up Your Integrated Qualification SystemIntegrated Qualification System 71Activating the On-Screen KeyboardActivating the On-Screen KeyboardYou

Strany 336

Certification Informationviii IQS-600European Community Declaration of ConformityAn electronic version of the declaration of conformity for your produ

Strany 337

Setting Up Your Integrated Qualification System72 IQS-600Activating the On-Screen KeyboardTo select the keyboard type:1. In the main window, select th

Strany 338 - ReadBinary

Setting Up Your Integrated Qualification SystemIntegrated Qualification System 73Installing a MouseInstalling a MouseYour IQS-600 Integrated Qualifica

Strany 339 - Initialize

Setting Up Your Integrated Qualification System74 IQS-600Installing a Tape, CD, or DVD PlayerInstalling a Tape, CD, or DVD PlayerYour IQS-600 Integrat

Strany 340 - RemoteState

Setting Up Your Integrated Qualification SystemIntegrated Qualification System 75Installing a Headset or a SpeakerInstalling a Headset or a SpeakerYou

Strany 341 - StatusByte

Setting Up Your Integrated Qualification System76 IQS-600Installing a MicrophoneInstalling a MicrophoneYour IQS-600 Integrated Qualification System ca

Strany 342 - ReturnToLocal

Setting Up Your Integrated Qualification SystemIntegrated Qualification System 77Installing a PrinterInstalling a PrinterYour IQS-600 Integrated Quali

Strany 343 - F Using the IQS-9600 Utility

Setting Up Your Integrated Qualification System78 IQS-600Selecting the Startup InterfaceSelecting the Startup InterfaceYou can select whether or not I

Strany 344 - 336 IQS-600

Setting Up Your Integrated Qualification SystemIntegrated Qualification System 79Customizing Access LevelsCustomizing Access LevelsYou cannot set pass

Strany 345

Setting Up Your Integrated Qualification System80 IQS-600Customizing Access LevelsTo customize access levels:1. In the main window, select the Utiliti

Strany 346

Setting Up Your Integrated Qualification SystemIntegrated Qualification System 81Setting Up Auto Logon for WindowsSetting Up Auto Logon for WindowsNot

Strany 347

Integrated Qualification System 11 Introducing the IQS-600 Integrated Qualification SystemMain FeaturesThe IQS-600 Integrated Qualification System is

Strany 348

Setting Up Your Integrated Qualification System82 IQS-600Setting Up Auto Logon for Windows3. In the Run box, type control userpasswords2, then select

Strany 349

Setting Up Your Integrated Qualification SystemIntegrated Qualification System 83Setting Up Auto Logon for Windows5. Select the User name box, type th

Strany 350

Setting Up Your Integrated Qualification System84 IQS-600Setting Communication ParametersSetting Communication ParametersFor information on communicat

Strany 351

Setting Up Your Integrated Qualification SystemIntegrated Qualification System 85Adjusting the Fan SpeedTo adjust the fan speed:1. In the main window,

Strany 352

Setting Up Your Integrated Qualification System86 IQS-600Saving and Opening ConfigurationsSaving and Opening ConfigurationsIt is possible to save as m

Strany 353

Setting Up Your Integrated Qualification SystemIntegrated Qualification System 87Saving and Opening ConfigurationsTo load a configuration:1. Select th

Strany 354

Setting Up Your Integrated Qualification System88 IQS-600Saving the Configuration on ExitingSaving the Configuration on ExitingIQS Manager offers you

Strany 355 - ₼⦌␂ℝ☀⹂䓸德棟Ⓟ䤓屓⸩

Setting Up Your Integrated Qualification SystemIntegrated Qualification System 89Changing Unit and Module IdentificationChanging Unit and Module Ident

Strany 356 - MARKING REQUIREMENTS

Setting Up Your Integrated Qualification System90 IQS-600Changing Unit and Module Identification4. Change the unit or module name and number as desire

Strany 357

Setting Up Your Integrated Qualification SystemIntegrated Qualification System 91Reverting to Factory SettingsReverting to Factory SettingsYou might n

Komentáře k této Příručce