Exfo PPM-350C PON Power Meter Uživatelský manuál Strana 23

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 47
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 22
PPM-350C 17
To test in Pass/Fail or Normal mode:
1. Inspect your fibers and clean them properly if needed (see Cleaning and
Connecting Optical Fibers on page 11 for details).
2. Connect as shown:
3. Tur n unit on.
4. If you want to test in Pass/Fail mode:
Ensure that LEDs are on. If not, press .
Ensure that the desired threshold set is selected (see Selecting a Threshold
Set on page 14).
Results are now available.
Test at the premises
Tes t j u m p e r
ONT port
Tes t jum p e r
OLT/video port
Drop cable
Bulkhead connector
Test at the drop terminal
Tes t jum p e r
ONT port
Tes t j u m p e r
OLT/video port
Bulkhead connector
Drop cable
ONT port
Tes t j u m p e r
OLT/video port
Splitter’s output pigtail
Bulkhead connector
Te s t ju m pe r
Test at the fiber distribution hub (FDH)
P/F
mode
Zobrazit stránku 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 46 47

Komentáře k této Příručce

Žádné komentáře