Exfo FTB-7000 OTDR Series for FTB-500 Uživatelský manuál Strana 411

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 489
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 410
Referencia de instrucciones SCPI
OTDR 397
Product-Specific Commands—Description
:CONFigure[1..n]:ANAlysis:THReshold:
EOFiber?
Description This query returns the end-of-fiber threshold that
will be used for the next acquisition.
*RST reverts this setting to default value.
Syntax :CONFigure[1..n]:ANAlysis:THReshold:EOFiber?[
<wsp>MINimum|MAXimum|DEFault]
Parameter(s) Parameter 1:
The program data syntax for the first parameter is
defined as a <CHARACTER PROGRAM DATA>
element. The allowed <CHARACTER PROGRAM
DATA> elements for this parameter are:
MINimum|MAXimum|DEFault.
MINimum is used to retrieve the instrument's
lowest supported value.
MAXimum is used to retrieve the instrument's
highest supported value.
DEFault is used to retrieve the instrument's
default value.
Response Syntax <End-of-Fiber>
Response(s) End-of-Fiber:
The response data syntax for <End-of-Fiber> is
defined as a <NR3 NUMERIC RESPONSE DATA>
element.
Returns the end-of-fiber threshold.
Example(s) CONF:ANA:THR:EOF 5.5
CONF:ANA:THR:EOF? Returns 5.5
Zobrazit stránku 410
1 2 ... 406 407 408 409 410 411 412 413 414 415 416 ... 488 489

Komentáře k této Příručce