Exfo FTB-8500 Series for FTB-200 Uživatelský manuál Strana 155

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 513
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 154
I/F Setup Tabs
Ethernet and Fibre Channel Application 141
Interface
Port Status: Indicates the status of the port login process. Possible
status are:
Logged-in: The login process has completed successfully.
Failed: The login process has not been able to complete the login
process or an error has been detected. However, traffic can still be
transmitted.
In Progress: The login process is running (not completed yet).
Logged-out: The system has not logged in yet, has received a valid
Logout command from the remote port, the Login check box has been
cleared, or the Fabric Status is either Failed, In Progress, or Logged
Out.
Login button: Allows the initiation of the Login process with the
selected Advertised BB_Credit when the Enable Login check box is
selected. Changing the Advertised BB_Credit requires to manually
re-send a login using the Login button. The capability to log in is
available only with Framed Layer 2 when a successful link has been
established.
Zobrazit stránku 154
1 2 ... 150 151 152 153 154 155 156 157 158 159 160 ... 512 513

Komentáře k této Příručce

Žádné komentáře