Bit Pattern Analysis and the Gearbox
88 PSO-200
Performing Detailed Bit Pattern Analysis with the Gearbox
Gearbox Streaming Types
Depending on how the bit pattern is sent to your transmitter, the Gearbox
can be configured as follows:
One global stream – a single known encoded data stream is
demultiplexed inside the transmitter into several parallel sub-streams
sent to the modulator, with delays and inversions (if any).
N individual streams – as many encoded data streams as there are bits
per symbol (four in the example diagram) are sent with known delays
and inversions, if any, to the same number of modulators.
Dual X-Y streams (dual-polarization modulations only) – two known
encoded data streams corresponding to the X and Y states of
polarization are demultiplexed inside the transmitter into parallel
streams sent to the modulators.
Note: If the transmitter has an internal encoder, it is the encoded data that must
be input to the Gearbox.