Test Results
296 FTB-700G/800 Series
Alarms/Errors
The following settings are only available with Carrier Ethernet OAM test
application.
Address Type defines the destination address type of the frame:
Unicast or Multicast (default).
Priority
1
allows to select the VLAN user priority: 0 (default) to 7.
Refer to VLAN ID and Priority on page 575 for more information.
Drop Eligible
1
is set to No (no frames will be dropped when
congestion occurs) and is not configurable.
MEG Level (Y.1731 and MEF) is the Maintenance Entity Group
Level configurable from 0 to 7 (default).
Period determines the transmission period of frames: 1 s (default)
and 1 min. Not available with C-DCI.
Amount, only available with C-DCI alarm, is set to 1.
Note: The RDI alarm is available when the CC Function is enabled and is using
the parameters from the CC Function (refer to page 184 for more
information).
1. Available when VLAN is enabled.(see
VLAN
on page 168)