Test Results
NetBlazer 367
Summary (SyncE)
RX
Last QL Message indicates the last Quality Level value received. The
pass/fail verdict is also displayed when both QL Mismatch Monitoring
and Pass/Fail Verdict check boxes are selected.
Last Change indicates the date and time of the Last QL Message has
changed.
Information/Event Count gives respectively the count of information
and event frames generated for all Quality Level values.
QL Mismatch Frame Count gives the total count of information and/or
event frames received not matching the expected Quality Level. Only
available when the QL Mismatch Monitoring check box is selected.
Frequency/Offset indicates respectively the frequency and the offset
between the standard rate specification and the rate of the input signal.
Max. (-/+) Offset (ppm) indicates respectively the minium and
maximum offset between the standard rate specification and the
largest/smallest rate recorded from the received signal.
TX
QL Message indicates the Quality Level value that is generated.
Last Change indicates the date and time of the QL Message value has
changed. For 1GE Electrical interface using Local Clock set to Slave,
the Last Change is not available.
Information/Event Count gives respectively the count of information
and event frames generated for all Quality Level values. Event Count is
not available with 1GE Electrical interface using remote local clock.