Test Results
NetBlazer 365
Summary (S-OAM)
RX Line Utilization meter and value, available with Loopback
function, indicate the line rate utilization percentage (only LBR frames
are considered) received in the last second.
TST RX Rate meter and value, available with Test function, indicate the
quantity of TST frames received in the last second.
Frame Delay meter and value, available with Frame Delay function,
indicate the average of the measured frame delays in the last second.
Frame Loss Ratio meter, available with Frame Loss function,
indicates for both Near-End and Far-End the last measured frame loss
ratio in the last second.
Synthetic Loss Ratio meter, available with Synthetic Loss function,
indicates for both Near-End and Far-End the last measured Synthetic
Loss ratio in the last second.
Note: Refer to S-OAM on page 324 for more alarms/errors/statistics information.
Summary
Note: Refer to S-OAM on page 324 for more information on alarms.
Thresholds
Refer to Thresholds on page 182 for more information.