Auto Tests
56 AXS-200/635i
Configuring Final/Active Pair Test
To set parameter values:
1. Press the up/down arrow keys to highlight the desired parameter.
2. Press to display the list or select the value.
3. Press the up/down arrow key to highlight the desired value.
OR
4. Press the left arrow key to erase the existing value, and then use the
alphanumeric keypad to enter a value. To cancel the entry, press .
5. Press to accept the value.
Thresholds 1
The Thresholds 1 tab displays the
threshold parameters for the
Final/Active Pair Test. They are part of
the CQ profile and cannot be edited on
this pane.
The parameters are described below:
³ Max. On Hook AC/DC Voltage are
the maximum AC/DC threshold
voltage values for the circuit.
³ Min. Loop Current (mA) is the minimum loop current for the circuit
in mA.
³ Max. Ground Resistance (Ohm) is the maximum ground resistance
in Ohm.
Note: The Ground Resistance function only works with central offices with the tip
connected to ground.