Exfo FTB-635 Wideband Copper and DSL Test Module Uživatelský manuál Strana 213

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 373
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 212
RFL Test
Copper and xDSL Tests 205
RFL-2-Wire
The page displays single pair RFL test results. Based on the cable
condition, corresponding values are added into the diagram at their
specific positions. Test result units are dependent on Standard in
Setup/Application Settings.
Distance to strap (DTS).
Resistance to strap (RTS).
Distance from fault to strap (DFTS).
Resistance from fault to strap (RFTS).
Resistance to fault (RTF).
Distance to fault (DTF).
Faulted cable (FC).
Resistance at Fault (Rf) is the ohms of the fault only.
Voltage at fault (Vf).
If the test reports that it cannot detect the strap when the measured
loop resistance is >10 k Ohm, this may mean:
There is no strap connected.
There is a strap, but the cable is too long and has a loop resistance
>10 k Ohm.
There is a strap, but there is a high resistance fault or open in the
cable.
The connection (leads or strap) may be faulty.
The resistance test may be used to troubleshoot this problem.
Fault Status displays the status of the RFL test.
Test Status displays the current state of measurement or an error
message.