Exfo FTB-635 Wideband Copper and DSL Test Module Uživatelský manuál Strana 269

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 373
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 268
Noise Tests
Copper and xDSL Tests 261
NEXT
Setting Spectrum Test Thresholds
The Test Thresholds page allows you to set the Spectrum Mode
Thresholds.
To set the Threshold values:
1. From the Copper main menu Test Groups, select Noise test
.
2. From the Tests menu, select NEXT test.
3. Tap Spectrum tab.
4. Tap Edit Thresholds button to open the Test Thresholds page.
5. Set the threshold values as required.
6. Tap Close to confirm and exit the page.
The page allows you to set the following parameters:
Threshold is the threshold limit for each pair: Maximum, Minimum, or
None which disables the threshold. In this case, the pass/fail status
indicator will not be displayed.
Crosstalk allows you to edit the NEXT threshold values for all
bandwidths.
Zobrazit stránku 268
1 2 ... 264 265 266 267 268 269 270 271 272 273 274 ... 372 373

Komentáře k této Příručce

Žádné komentáře